Performance Testing Methodology
Performance Testing Methodology: High-Density Compute Platform (Model PTP-9000)
This document details the comprehensive technical specifications, performance validation methodology, and recommended deployment scenarios for the High-Density Compute Platform, Model PTP-9000. This configuration is specifically engineered for rigorous, repeatable performance benchmarking and mission-critical, high-throughput workloads.
1. Hardware Specifications
The PTP-9000 platform is built upon a dual-socket, 4U rackmount chassis, designed for maximum component density and thermal efficiency. All components selected prioritize low-latency access and high aggregate throughput, crucial for accurate performance measurement under sustained load.
1.1 System Chassis and Motherboard
The foundation of the PTP-9000 is the proprietary Titan-V 4U chassis, which features redundant, hot-swappable power supplies and high-airflow fan modules (N+1 configuration).
Specification | Value |
---|---|
Form Factor | 4U Rackmount |
Motherboard Model | Supermicro X13DGQ-TF (Custom BIOS v4.12.0) |
PSU Configuration | 2x 2200W Titanium-rated (1+1 Redundant) |
Cooling Solution | Direct-to-Chip Liquid Cooling (Optional) or High-Static Pressure Air Cooling Array |
Maximum Node Capacity | 2 Sockets |
1.2 Central Processing Units (CPUs)
The selection criterion for the CPUs focused on maximizing core density, high L3 cache size, and superior Instruction Per Cycle (IPC) performance at sustained turbo frequencies.
The standard configuration utilizes dual-socket Intel Xeon Scalable Processors, 4th Generation (Sapphire Rapids).
Parameter | Processor 1 (Primary) | Processor 2 (Secondary) |
---|---|---|
Model | Intel Xeon Platinum 8480+ | Intel Xeon Platinum 8480+ |
Cores / Threads | 56 Cores / 112 Threads | 56 Cores / 112 Threads |
Base Clock Frequency | 2.4 GHz | 2.4 GHz |
Max Turbo Frequency (Single Core) | Up to 3.8 GHz | Up to 3.8 GHz |
L3 Cache (Total) | 112 MB | 112 MB |
TDP (Thermal Design Power) | 350W | 350W |
Total System Cores/Threads | 112 Cores / 224 Threads |
Specific attention must be paid to CPU Power Management during testing; performance validation typically requires setting the BIOS power profile to "Maximum Performance" to prevent dynamic frequency throttling under sustained load.
1.3 Memory Subsystem (RAM)
The memory configuration is optimized for high bandwidth and low latency, utilizing all available memory channels (8 channels per CPU socket). The testing configuration mandates the use of high-speed DDR5 ECC Registered DIMMs.
Parameter | Specification |
---|---|
Type | DDR5 ECC Registered (RDIMM) |
Total Capacity | 2048 GB (2 TB) |
Module Density | 16 x 128 GB DIMMs |
Speed / Data Rate | 4800 MT/s (JEDEC Standard) |
Latency (CL) | CL40 |
Interleaving Schema | 8-Way per CPU (Total 16-Way) |
For memory bandwidth testing, the configuration should be validated against the JEDEC standard maximum theoretical throughput, which for this setup is approximately 614.4 GB/s aggregate.
1.4 Storage Subsystem
Storage performance is a critical bottleneck in many high-performance applications. The PTP-9000 employs a tiered NVMe storage array managed by a high-throughput PCIe Gen 5 RAID controller.
The primary boot/OS drive is a small, high-endurance U.2 drive, while the bulk storage for benchmarking datasets resides on the high-speed array.
Component | Specification |
---|---|
Controller | Broadcom MegaRAID 9750-16i (PCIe 5.0 x16 interface) |
Drives Installed | 8 x 3.84 TB U.2 NVMe SSDs (Enterprise Grade) |
Drive Model Example | Samsung PM1743 equivalent |
RAID Level | RAID 10 (for redundancy and performance) |
Aggregate Capacity (Usable) | Approx. 12.2 TB |
Targeted Sequential Read/Write (RAID 10) | > 30 GB/s |
Targeted Random IOPS (4K QD64) | > 8,000,000 IOPS |
The storage subsystem is connected via dedicated PCIe Gen 5 lanes, bypassing the chipset where possible to ensure direct CPU access, as detailed in the PCIe Lane Allocation Document.
1.5 Networking Interface Cards (NICs)
For network-intensive performance testing (e.g., distributed computing simulations or high-frequency trading), the PTP-9000 includes dual 200 Gigabit Ethernet interfaces managed by specialized offload engines.
Interface | Specification |
---|---|
Primary Fabric | 2x 200GbE (QSFP-DD) |
Controller Chipset | NVIDIA ConnectX-6 Dx / Mellanox equivalent |
Bus Interface | PCIe Gen 5 x16 |
Offload Capabilities | RDMA over Converged Ethernet (RoCEv2), TCP Segmentation Offload (TSO) |
These interfaces are mandatory for validating network latency metrics detailed in Section 4.2.
2. Performance Characteristics
Performance validation for the PTP-9000 configuration involves a multi-faceted approach, encompassing synthetic benchmarks, standardized industry tests, and application-specific workload simulations. The goal is to establish a high-water mark for current server technology in this form factor.
2.1 Synthetic Benchmarking Results
Synthetic benchmarks provide a baseline measurement of raw hardware capability across compute, memory, and I/O subsystems. All tests were executed after a 48-hour "burn-in" period to ensure component stabilization.
2.1.1 Compute Performance (CPU-Bound)
We utilize SPEC CPU 2017 benchmarks, focusing on the integer (SPECint) and floating-point (SPECfp) metrics, measured in SPECrate (multi-threaded performance).
Metric | Score (PTP-9000) | Reference Baseline (Previous Gen Dual-Socket) |
---|---|---|
SPECint_rate_base2017 | 1150 | 780 |
SPECfp_rate_base2017 | 1580 | 1050 |
Estimated Peak FLOPS (FP64) | ~14.5 TFLOPS | ~9.0 TFLOPS |
The significant uplift in SPECfp is attributed to the enhanced AVX-512 capabilities and the increased core count introduced by the Sapphire Rapids generation.
2.1.2 Memory Bandwidth and Latency
Using STREAM benchmark tools (Suites for Memory Bandwidth), we measure the effective throughput achieved across the entire 2TB memory pool.
Operation | Theoretical Max (GB/s) | Measured Throughput (GB/s) | Efficiency (%) |
---|---|---|---|
Copy | 614.4 | 552.8 | 90.0% |
Scale | 614.4 | 551.1 | 89.7% |
Add | 409.6 | 367.6 | 89.7% |
The efficiency rate of 90% is considered excellent for a fully populated, high-capacity DDR5 system, indicating minimal synchronization overhead across the 16 memory channels.
2.1.3 Storage I/O Performance
Storage performance is measured using FIO (Flexible I/O Tester) targeting the RAID 10 array configured in Section 1.4.
Workload Type | Block Size | IOPS (Read/Write) | Latency (99th Percentile, $\mu s$) |
---|---|---|---|
Sequential Read | 128K | 550,000 IOPS / 28.5 GB/s | 150 $\mu s$ |
Random Read (4K) | 4K | 1,850,000 IOPS | 32 $\mu s$ |
Random Write (4K) | 4K | 1,600,000 IOPS | 45 $\mu s$ |
The low 99th percentile latency is critical for database workloads, confirming the low-overhead access provided by the PCIe Gen 5 lanes to the NVMe drives.
2.2 Real-World Application Metrics
While synthetic tests establish capability, real-world metrics define utility. We focus on established workload simulation environments.
2.2.1 High-Performance Computing (HPC)
For HPC validation, the LINPACK benchmark (which directly stresses FP64 operations and memory access patterns) is used.
- **HPL Test Result:** The system achieved a sustained performance of **13.8 TFLOPS** (FP64, Rpeak utilization of 95.1%), which is a crucial metric for comparing against high-performance computing cluster nodes. This requires aggressive tuning of MPI communication buffers.
2.2.2 Virtualization Density
To test density, we deployed standard enterprise Linux virtual machines (VMs) running typical microservices stacks (compiling code, running light web servers).
- **Metric:** Maximum stable VM density before observable performance degradation (defined as >10% latency increase).
- **Result:** 95 concurrent VMs stabilized at 70% CPU utilization, with memory pressure being the limiting factor rather than CPU contention. This highlights the effectiveness of the 2TB memory capacity.
2.2.3 Database Transaction Processing
Using the TPC-C benchmark simulation (representing Online Transaction Processing - OLTP), we measure Transactions Per Minute (TPM).
- **Result:** The PTP-9000 configuration achieved **750,000 TPM** (New Orders per Minute) at a 100% transaction mix, placing it in the top tier for single-node OLTP performance, heavily reliant on the storage subsystem's low latency.
- 2.3 Thermal and Power Performance Under Load
Sustained performance requires stable thermal management. During the 24-hour HPL run, system telemetry was continuously monitored.
- **Peak CPU Die Temperature:** 82°C (Max safe threshold: 100°C)
- **Total System Power Draw (Peak Load):** 1450W (Measured at the PDU input, excluding network switch overhead).
This demonstrates that the cooling solution is adequate for maintaining maximum turbo frequencies without thermal throttling for extended periods, a key differentiator from lower-density systems.
3. Recommended Use Cases
The PTP-9000 configuration is not intended for general-purpose workloads. Its high component density, specialized I/O throughput, and substantial memory capacity make it optimally suited for environments where latency and aggregate throughput are paramount.
3.1 High-Performance Computing (HPC) and Simulation
The combination of 112 physical cores, high FP64 capability, and massive RAM capacity makes this platform ideal for:
- **Computational Fluid Dynamics (CFD):** Running complex, memory-intensive fluid simulations that benefit from the high memory bandwidth.
- **Molecular Dynamics:** Simulating protein folding or material interactions, which stress both core count and double-precision floating-point execution units.
- **Large-Scale Weather Modeling:** Serving as a primary node in regional simulation clusters where inter-node communication (assisted by 200GbE RoCE) is critical.
3.2 Database and Big Data Acceleration
The storage subsystem, capable of sustained multi-gigabyte per second transfer rates with sub-50 $\mu s$ latency, targets specific database workloads:
- **In-Memory Databases (IMDB):** While the system supports 2TB RAM, it is particularly suited for IMDBs that require rapid caching of large datasets alongside transactional logging, leveraging the fast NVMe array for persistence layers.
- **Real-time Analytics Platforms:** Environments processing high-velocity time-series data (e.g., financial market feeds or IoT telemetry) where data ingestion rate must match processing speed.
3.3 Mission-Critical Virtualization and Consolidation
For organizations consolidating legacy workloads onto modern hardware, the PTP-9000 offers extreme consolidation ratios.
- **High-Density Container Hosts:** Deploying Kubernetes nodes requiring large amounts of dedicated memory per pod, such as large Java Virtual Machines (JVMs) or complex AI/ML inference services.
- **High-Throughput VDI:** Serving environments where hundreds of users require dedicated resources without experiencing noticeable resource contention.
Consult the Workload Profiling Guide before deploying general web serving or low-I/O workloads, as the cost-to-performance ratio is suboptimal for those tasks.
4. Comparison with Similar Configurations
To contextualize the PTP-9000's capabilities, it is essential to compare it against two common alternatives: a density-optimized 1U configuration and a higher-core-count, but lower-frequency, alternative.
4.1 Configuration Benchmarks
| Feature | PTP-9000 (4U High-Performance) | 1U Density Model (e.g., Dual-Socket 128 Core) | 2U High-Core Model (e.g., AMD EPYC Genoa) | | :--- | :--- | :--- | :--- | | **CPU Configuration** | 2x Xeon Platinum 8480+ (112C) | 2x High-Efficiency Xeon Gold (128C Total) | 2x AMD EPYC 9654 (192C Total) | | **Total RAM Capacity** | 2 TB (DDR5-4800) | 1 TB (DDR5-4800) | 3 TB (DDR5-4800) | | **Max Storage Bays** | 8x U.2 NVMe (PCIe 5.0) | 10x 2.5" SATA/SAS | 16x 2.5" SAS/SATA + 4x U.2 | | **Network Throughput** | 200GbE Native | 100GbE Standard | 100GbE Standard | | **SPECfp_rate_base2017** | **1580** | 1100 | 1950 | | **Storage IOPS (4K Random)** | **1.8 Million** | 400,000 | 1.2 Million | | **Primary Advantage** | Lowest Latency, Highest Single-Thread IPC | Highest Core Density per Rack Unit | Highest Absolute Core Count |
The PTP-9000 excels where memory bandwidth and low-latency storage access are more critical than maximizing the total core count (as seen in the AMD 2U alternative) or fitting into a constrained space (as seen in the 1U density model). The Intel architecture provides a superior single-threaded performance profile which benefits latency-sensitive applications.
4.2 Latency Comparison
A critical differentiator for performance testing is the consistency of latency. The following table illustrates typical random read latency under varying concurrent access loads.
Load Level (Concurrent Threads) | PTP-9000 (Target Latency $\mu s$) | 1U Density Model ($\mu s$) | 2U High-Core Model ($\mu s$) |
---|---|---|---|
16 Threads | 28 | 35 | 40 |
128 Threads | 38 | 85 | 75 |
512 Threads (Max Stress) | 55 | 210 | 150 |
The PTP-9000's dedicated PCIe Gen 5 lanes and superior memory controller design (detailed in Platform Architecture Overview) result in significantly lower latency degradation as load increases. This makes it the superior choice for environments requiring predictable Quality of Service (QoS).
5. Maintenance Considerations
Deploying a high-TDP, high-density platform like the PTP-9000 requires strict adherence to operational guidelines concerning power delivery, cooling infrastructure, and component replacement procedures. Failure to meet these requirements will lead to thermal throttling and premature hardware failure.
5.1 Power Requirements and Redundancy
With two 350W CPUs and a substantial NVMe array, the system demands significant, clean power.
- **Maximum Continuous Power Draw:** 1450W (under full synthetic load).
- **Peak Inrush Current:** Requires PDU circuits rated for at least 16A at 208V (or 20A at 120V, though 208V is strongly recommended for efficiency).
- **PSU Configuration:** The dual Titanium-rated 2200W PSUs ensure that the system can handle brief power spikes or the failure of one PSU while maintaining full operational capacity.
All installations must utilize UPS systems capable of sustaining the full 1450W load for a minimum of 15 minutes to allow for graceful shutdown or failover.
5.2 Thermal Management and Airflow
The PTP-9000 chassis is engineered for high static pressure cooling, meaning standard, low-pressure data center fans may be insufficient.
- **Minimum Required Static Pressure:** 1.5 inches of H2O at the chassis intake face.
- **Ambient Inlet Temperature:** Maximum sustained temperature must not exceed 25°C (77°F). Temperatures above this threshold will trigger aggressive fan speed increases, potentially exceeding noise limitations and stressing the PSU capacitors.
- **Liquid Cooling Option:** For environments exceeding 30°C ambient or requiring silent operation, the optional direct-to-chip liquid cooling loop (requiring a compatible CDU) is highly recommended. This reduces internal component temperatures by an average of 15°C under load.
Proper cable management is crucial to prevent obstruction of the front-to-back airflow path, as documented in the Cable Management Standards.
5.3 Firmware and Component Lifecycle Management
Maintaining peak performance requires rigorous firmware control. The testing environment mandates a strict update schedule.
- **BIOS/Firmware:** Must be updated to the latest validated version (currently BIOS v4.12.0 or later) to ensure optimal memory training and power state management for the DDR5 modules.
- **Storage Controller Firmware:** NVMe drive firmware must be synchronized with the RAID controller firmware to prevent I/O stalls related to command queue depth handling. Refer to the Compatibility Matrix before any storage maintenance.
- **Component Replacement:** Due to the density, replacement of DIMMs or PCIe cards often requires temporary removal of the upper CPU heat sink shroud. Hot-swapping is limited to the drives and fans; CPU and RAM are field-replaceable units (FRUs) requiring system shutdown.
Regular auditing of component health using SMART data and hardware monitoring tools (like IPMI/Redfish) is essential for predictive maintenance, particularly for the high-utilization NVMe drives.
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️