Core Network
```mediawiki
- Core Network Server Configuration - Technical Documentation
This document details the "Core Network" server configuration, a high-performance, highly-available system designed for demanding network infrastructure roles. This configuration prioritizes throughput, low latency, and redundancy.
1. Hardware Specifications
The "Core Network" configuration is built around a dual-socket server platform, leveraging enterprise-grade components for maximum reliability and performance. All components are chosen with a focus on minimizing single points of failure.
1.1 Processor
- **CPU Model:** Dual Intel Xeon Platinum 8480+ (32-Core, 56 Threads per CPU)
- **Base Frequency:** 2.0 GHz
- **Max Turbo Frequency:** 3.8 GHz
- **Cache:** 64 MB Intel Smart Cache per CPU
- **TDP (Thermal Design Power):** 350W per CPU
- **Instruction Set Extensions:** AVX-512, AES-NI, Intel VT-x, Intel VT-d
- **Socket Type:** LGA 4677
1.2 Memory
- **RAM Type:** 32 x 32GB DDR5 ECC Registered DIMMs
- **RAM Capacity:** 1 TB Total
- **RAM Speed:** 5600 MHz
- **RAM Configuration:** 8 DIMMs per CPU, configured for maximum memory bandwidth (8-channel)
- **Memory Protection:** ECC (Error-Correcting Code) for data integrity. Memory ECC details the importance of this feature.
1.3 Storage
- **Boot Drive:** 2 x 960GB NVMe PCIe 4.0 SSD (RAID 1 Mirroring) - Samsung PM1733 or equivalent. Used for OS and critical system files.
- **Data Storage:** 8 x 8TB SAS 12Gbps 7.2K RPM Enterprise Hard Drives (RAID 6) - Seagate Exos X18 or equivalent. Provides large capacity and redundancy for network data storage (e.g., packet captures, logging). RAID Configurations provides a deep dive into RAID levels.
- **Cache Tier:** 4 x 1.92TB NVMe PCIe 4.0 SSD (RAID 10) - Intel Optane P5800 or equivalent. Used as a read/write cache for the SAS drives, significantly improving I/O performance. SSD Caching explains this technology.
- **Storage Controller:** Broadcom MegaRAID SAS 9460-8i with 8GB NV Cache. Hardware RAID controller offering high performance and reliability. Storage Controllers outlines the different controller types.
- **Total Raw Storage:** Approximately 80 TB (HDD + SSD)
1.4 Network Interface Cards (NICs)
- **100GbE Uplink:** 2 x Dual-Port 100GbE QSFP28 NICs (Mellanox ConnectX-7 or equivalent). Provides high-bandwidth connectivity to the core network. Network Interface Cards details the different types of NICs.
- **10GbE Management:** 2 x 10GbE SFP+ NICs (Intel X710-DA4 or equivalent). Dedicated NICs for out-of-band management. Out-of-Band Management outlines its benefits.
- **NIC Teaming/Bonding:** Both 100GbE ports are configured in a Link Aggregation Control Protocol (LACP) team for redundancy and increased bandwidth.
1.5 Power Supply
- **Power Supply Units (PSUs):** 2 x 1600W 80+ Titanium Certified Redundant PSUs. Provides ample power with redundancy, preventing downtime due to PSU failure. Redundant Power Supplies details the benefits.
- **Power Distribution:** Dual power feeds from separate power circuits.
1.6 Chassis & Cooling
- **Chassis Type:** 2U Rackmount Server Chassis.
- **Cooling:** Redundant Hot-Swap Fans with N+1 redundancy. High static pressure fans optimized for efficient heat dissipation. Server Cooling Systems details the cooling options available.
- **Remote Management:** Integrated IPMI 2.0 compliant Remote Management Controller (BMC) with dedicated network port.
1.7 Motherboard
- **Chipset:** Intel C621A
- **Form Factor:** ATX
- **Expansion Slots:** Multiple PCIe 4.0 x16 slots for future expansion.
2. Performance Characteristics
This configuration is designed for high throughput and low latency, critical for core network functions.
2.1 CPU Performance
- **SPECint 2017:** Approximately 180 (estimated based on 8480+ benchmarks)
- **SPECfp 2017:** Approximately 250 (estimated based on 8480+ benchmarks)
- **Real-World Performance:** Excellent performance in packet processing, routing, and firewall tasks. The high core count and AVX-512 instruction set are particularly beneficial for these workloads.
2.2 Storage Performance
- **Boot Drive (RAID 1):** Sequential Read: 7000 MB/s, Sequential Write: 5500 MB/s, IOPS: 600K
- **Data Storage (RAID 6 with Cache):** Sequential Read: 5000 MB/s (with cache hits), Sequential Write: 3000 MB/s (with cache writes), IOPS: 150K (sustained). Without cache, performance will be significantly lower, highlighting the importance of the Optane cache tier.
- **Latency:** Average latency for data storage is under 5ms with the cache in place.
2.3 Network Performance
- **100GbE Throughput:** Up to 95 Gbps sustained throughput with appropriate network hardware.
- **Latency:** Sub-microsecond latency for packet forwarding.
- **Packet Loss:** Negligible packet loss under heavy load.
2.4 Benchmarks
The following table summarizes some key benchmark results:
Benchmark | Result |
---|---|
SPECint 2017 (estimated) | 180 |
SPECfp 2017 (estimated) | 250 |
Iometer (RAID 6 + Cache) - Sequential Read | 5000 MB/s |
Iometer (RAID 6 + Cache) - Sequential Write | 3000 MB/s |
iperf3 (100GbE) | 95 Gbps |
3. Recommended Use Cases
The "Core Network" configuration is ideally suited for the following applications:
- **Core Routing:** Serving as the central router in a large network. Network Routing provides a detailed overview.
- **Firewall/Security Appliance:** Handling high-volume network security traffic. Firewall Technologies outlines common firewall solutions.
- **Deep Packet Inspection (DPI):** Analyzing network traffic for security threats and performance monitoring. Deep Packet Inspection describes this process.
- **Intrusion Detection/Prevention Systems (IDS/IPS):** Detecting and preventing malicious activity on the network. IDS/IPS Systems details the differences between these systems.
- **Network Monitoring & Analytics:** Collecting and analyzing network data for performance optimization and troubleshooting. Network Monitoring Tools are critical for this role.
- **SD-WAN Gateway:** Acting as a central point of control for a software-defined wide area network. SD-WAN explains this technology.
- **High-Frequency Trading (HFT) Network Infrastructure:** Low latency is paramount for HFT applications.
4. Comparison with Similar Configurations
The "Core Network" configuration represents a high-end solution. Here's a comparison with other potential configurations:
Configuration | CPU | RAM | Storage | Network | Estimated Cost | Ideal Use Case |
---|---|---|---|---|---|---|
**Entry-Level Network Server** | Dual Intel Xeon Silver 4310 | 64GB DDR4 ECC | 2 x 480GB SSD (RAID 1) | 2 x 10GbE SFP+ | $8,000 - $12,000 | Small business network, basic firewall |
**Mid-Range Network Server** | Dual Intel Xeon Gold 6338 | 128GB DDR4 ECC | 2 x 960GB SSD (RAID 1) + 4 x 4TB SAS (RAID 5) | 2 x 10GbE SFP+ + 1 x 40GbE QSFP+ | $18,000 - $25,000 | Medium-sized network, advanced firewall, IDS/IPS |
**Core Network (This Configuration)** | Dual Intel Xeon Platinum 8480+ | 1TB DDR5 ECC | 2 x 960GB NVMe (RAID 1) + 8 x 8TB SAS (RAID 6) + 4 x 1.92TB NVMe (RAID 10) | 2 x Dual-Port 100GbE QSFP28 + 2 x 10GbE SFP+ | $40,000 - $60,000 | Large enterprise network, core routing, high-security applications |
**High-End Network Server** | Dual Intel Xeon Platinum 8490+ | 2TB DDR5 ECC | 2 x 1.92TB NVMe (RAID 1) + 16 x 16TB SAS (RAID 6) + 8 x 3.84TB NVMe (RAID 10) | 4 x Dual-Port 100GbE QSFP28 + 4 x 10GbE SFP+ | $70,000+ | Mission-critical network infrastructure, extremely high-throughput applications |
5. Maintenance Considerations
Maintaining the "Core Network" configuration requires careful planning and execution.
5.1 Cooling
- **Ambient Temperature:** Maintain a server room temperature between 68°F (20°C) and 77°F (25°C). Data Center Cooling provides best practices.
- **Fan Monitoring:** Regularly monitor fan speeds and temperatures using the IPMI interface.
- **Dust Control:** Implement a regular dust removal schedule to prevent overheating.
5.2 Power Requirements
- **Total Power Consumption:** Approximately 1000W - 1500W under full load.
- **Power Circuit:** Dedicated power circuits are required to handle the power draw.
- **UPS:** An Uninterruptible Power Supply (UPS) is essential to protect against power outages. UPS Systems details the different UPS technologies.
5.3 Storage Maintenance
- **RAID Monitoring:** Continuously monitor the RAID array status for any errors or failures.
- **Drive Replacement:** Have spare drives on hand for immediate replacement in case of failure.
- **Firmware Updates:** Keep storage controller and drive firmware up to date.
5.4 Network Maintenance
- **NIC Monitoring:** Monitor NIC performance and error rates.
- **Cable Management:** Maintain organized cable management for easy troubleshooting.
- **Firmware Updates:** Keep NIC firmware up-to-date. Network Device Management covers broader network maintenance.
5.5 Software Updates
- **OS and Driver Updates:** Apply regular operating system and driver updates to ensure security and stability. Server Operating Systems provides information on various OS options.
- **Firmware Updates:** Update server firmware (BIOS, BMC) to the latest versions.
```
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️