Core Network

From Server rental store
Jump to navigation Jump to search

```mediawiki

  1. Core Network Server Configuration - Technical Documentation

This document details the "Core Network" server configuration, a high-performance, highly-available system designed for demanding network infrastructure roles. This configuration prioritizes throughput, low latency, and redundancy.

1. Hardware Specifications

The "Core Network" configuration is built around a dual-socket server platform, leveraging enterprise-grade components for maximum reliability and performance. All components are chosen with a focus on minimizing single points of failure.

1.1 Processor

  • **CPU Model:** Dual Intel Xeon Platinum 8480+ (32-Core, 56 Threads per CPU)
  • **Base Frequency:** 2.0 GHz
  • **Max Turbo Frequency:** 3.8 GHz
  • **Cache:** 64 MB Intel Smart Cache per CPU
  • **TDP (Thermal Design Power):** 350W per CPU
  • **Instruction Set Extensions:** AVX-512, AES-NI, Intel VT-x, Intel VT-d
  • **Socket Type:** LGA 4677

1.2 Memory

  • **RAM Type:** 32 x 32GB DDR5 ECC Registered DIMMs
  • **RAM Capacity:** 1 TB Total
  • **RAM Speed:** 5600 MHz
  • **RAM Configuration:** 8 DIMMs per CPU, configured for maximum memory bandwidth (8-channel)
  • **Memory Protection:** ECC (Error-Correcting Code) for data integrity. Memory ECC details the importance of this feature.

1.3 Storage

  • **Boot Drive:** 2 x 960GB NVMe PCIe 4.0 SSD (RAID 1 Mirroring) - Samsung PM1733 or equivalent. Used for OS and critical system files.
  • **Data Storage:** 8 x 8TB SAS 12Gbps 7.2K RPM Enterprise Hard Drives (RAID 6) - Seagate Exos X18 or equivalent. Provides large capacity and redundancy for network data storage (e.g., packet captures, logging). RAID Configurations provides a deep dive into RAID levels.
  • **Cache Tier:** 4 x 1.92TB NVMe PCIe 4.0 SSD (RAID 10) - Intel Optane P5800 or equivalent. Used as a read/write cache for the SAS drives, significantly improving I/O performance. SSD Caching explains this technology.
  • **Storage Controller:** Broadcom MegaRAID SAS 9460-8i with 8GB NV Cache. Hardware RAID controller offering high performance and reliability. Storage Controllers outlines the different controller types.
  • **Total Raw Storage:** Approximately 80 TB (HDD + SSD)

1.4 Network Interface Cards (NICs)

  • **100GbE Uplink:** 2 x Dual-Port 100GbE QSFP28 NICs (Mellanox ConnectX-7 or equivalent). Provides high-bandwidth connectivity to the core network. Network Interface Cards details the different types of NICs.
  • **10GbE Management:** 2 x 10GbE SFP+ NICs (Intel X710-DA4 or equivalent). Dedicated NICs for out-of-band management. Out-of-Band Management outlines its benefits.
  • **NIC Teaming/Bonding:** Both 100GbE ports are configured in a Link Aggregation Control Protocol (LACP) team for redundancy and increased bandwidth.

1.5 Power Supply

  • **Power Supply Units (PSUs):** 2 x 1600W 80+ Titanium Certified Redundant PSUs. Provides ample power with redundancy, preventing downtime due to PSU failure. Redundant Power Supplies details the benefits.
  • **Power Distribution:** Dual power feeds from separate power circuits.

1.6 Chassis & Cooling

  • **Chassis Type:** 2U Rackmount Server Chassis.
  • **Cooling:** Redundant Hot-Swap Fans with N+1 redundancy. High static pressure fans optimized for efficient heat dissipation. Server Cooling Systems details the cooling options available.
  • **Remote Management:** Integrated IPMI 2.0 compliant Remote Management Controller (BMC) with dedicated network port.

1.7 Motherboard

  • **Chipset:** Intel C621A
  • **Form Factor:** ATX
  • **Expansion Slots:** Multiple PCIe 4.0 x16 slots for future expansion.


2. Performance Characteristics

This configuration is designed for high throughput and low latency, critical for core network functions.

2.1 CPU Performance

  • **SPECint 2017:** Approximately 180 (estimated based on 8480+ benchmarks)
  • **SPECfp 2017:** Approximately 250 (estimated based on 8480+ benchmarks)
  • **Real-World Performance:** Excellent performance in packet processing, routing, and firewall tasks. The high core count and AVX-512 instruction set are particularly beneficial for these workloads.

2.2 Storage Performance

  • **Boot Drive (RAID 1):** Sequential Read: 7000 MB/s, Sequential Write: 5500 MB/s, IOPS: 600K
  • **Data Storage (RAID 6 with Cache):** Sequential Read: 5000 MB/s (with cache hits), Sequential Write: 3000 MB/s (with cache writes), IOPS: 150K (sustained). Without cache, performance will be significantly lower, highlighting the importance of the Optane cache tier.
  • **Latency:** Average latency for data storage is under 5ms with the cache in place.

2.3 Network Performance

  • **100GbE Throughput:** Up to 95 Gbps sustained throughput with appropriate network hardware.
  • **Latency:** Sub-microsecond latency for packet forwarding.
  • **Packet Loss:** Negligible packet loss under heavy load.

2.4 Benchmarks

The following table summarizes some key benchmark results:

Benchmark Result
SPECint 2017 (estimated) 180
SPECfp 2017 (estimated) 250
Iometer (RAID 6 + Cache) - Sequential Read 5000 MB/s
Iometer (RAID 6 + Cache) - Sequential Write 3000 MB/s
iperf3 (100GbE) 95 Gbps

3. Recommended Use Cases

The "Core Network" configuration is ideally suited for the following applications:

  • **Core Routing:** Serving as the central router in a large network. Network Routing provides a detailed overview.
  • **Firewall/Security Appliance:** Handling high-volume network security traffic. Firewall Technologies outlines common firewall solutions.
  • **Deep Packet Inspection (DPI):** Analyzing network traffic for security threats and performance monitoring. Deep Packet Inspection describes this process.
  • **Intrusion Detection/Prevention Systems (IDS/IPS):** Detecting and preventing malicious activity on the network. IDS/IPS Systems details the differences between these systems.
  • **Network Monitoring & Analytics:** Collecting and analyzing network data for performance optimization and troubleshooting. Network Monitoring Tools are critical for this role.
  • **SD-WAN Gateway:** Acting as a central point of control for a software-defined wide area network. SD-WAN explains this technology.
  • **High-Frequency Trading (HFT) Network Infrastructure:** Low latency is paramount for HFT applications.

4. Comparison with Similar Configurations

The "Core Network" configuration represents a high-end solution. Here's a comparison with other potential configurations:

Configuration CPU RAM Storage Network Estimated Cost Ideal Use Case
**Entry-Level Network Server** Dual Intel Xeon Silver 4310 64GB DDR4 ECC 2 x 480GB SSD (RAID 1) 2 x 10GbE SFP+ $8,000 - $12,000 Small business network, basic firewall
**Mid-Range Network Server** Dual Intel Xeon Gold 6338 128GB DDR4 ECC 2 x 960GB SSD (RAID 1) + 4 x 4TB SAS (RAID 5) 2 x 10GbE SFP+ + 1 x 40GbE QSFP+ $18,000 - $25,000 Medium-sized network, advanced firewall, IDS/IPS
**Core Network (This Configuration)** Dual Intel Xeon Platinum 8480+ 1TB DDR5 ECC 2 x 960GB NVMe (RAID 1) + 8 x 8TB SAS (RAID 6) + 4 x 1.92TB NVMe (RAID 10) 2 x Dual-Port 100GbE QSFP28 + 2 x 10GbE SFP+ $40,000 - $60,000 Large enterprise network, core routing, high-security applications
**High-End Network Server** Dual Intel Xeon Platinum 8490+ 2TB DDR5 ECC 2 x 1.92TB NVMe (RAID 1) + 16 x 16TB SAS (RAID 6) + 8 x 3.84TB NVMe (RAID 10) 4 x Dual-Port 100GbE QSFP28 + 4 x 10GbE SFP+ $70,000+ Mission-critical network infrastructure, extremely high-throughput applications

5. Maintenance Considerations

Maintaining the "Core Network" configuration requires careful planning and execution.

5.1 Cooling

  • **Ambient Temperature:** Maintain a server room temperature between 68°F (20°C) and 77°F (25°C). Data Center Cooling provides best practices.
  • **Fan Monitoring:** Regularly monitor fan speeds and temperatures using the IPMI interface.
  • **Dust Control:** Implement a regular dust removal schedule to prevent overheating.

5.2 Power Requirements

  • **Total Power Consumption:** Approximately 1000W - 1500W under full load.
  • **Power Circuit:** Dedicated power circuits are required to handle the power draw.
  • **UPS:** An Uninterruptible Power Supply (UPS) is essential to protect against power outages. UPS Systems details the different UPS technologies.

5.3 Storage Maintenance

  • **RAID Monitoring:** Continuously monitor the RAID array status for any errors or failures.
  • **Drive Replacement:** Have spare drives on hand for immediate replacement in case of failure.
  • **Firmware Updates:** Keep storage controller and drive firmware up to date.

5.4 Network Maintenance

  • **NIC Monitoring:** Monitor NIC performance and error rates.
  • **Cable Management:** Maintain organized cable management for easy troubleshooting.
  • **Firmware Updates:** Keep NIC firmware up-to-date. Network Device Management covers broader network maintenance.

5.5 Software Updates

  • **OS and Driver Updates:** Apply regular operating system and driver updates to ensure security and stability. Server Operating Systems provides information on various OS options.
  • **Firmware Updates:** Update server firmware (BIOS, BMC) to the latest versions.

```


Intel-Based Server Configurations

Configuration Specifications Benchmark
Core i7-6700K/7700 Server 64 GB DDR4, NVMe SSD 2 x 512 GB CPU Benchmark: 8046
Core i7-8700 Server 64 GB DDR4, NVMe SSD 2x1 TB CPU Benchmark: 13124
Core i9-9900K Server 128 GB DDR4, NVMe SSD 2 x 1 TB CPU Benchmark: 49969
Core i9-13900 Server (64GB) 64 GB RAM, 2x2 TB NVMe SSD
Core i9-13900 Server (128GB) 128 GB RAM, 2x2 TB NVMe SSD
Core i5-13500 Server (64GB) 64 GB RAM, 2x500 GB NVMe SSD
Core i5-13500 Server (128GB) 128 GB RAM, 2x500 GB NVMe SSD
Core i5-13500 Workstation 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000

AMD-Based Server Configurations

Configuration Specifications Benchmark
Ryzen 5 3600 Server 64 GB RAM, 2x480 GB NVMe CPU Benchmark: 17849
Ryzen 7 7700 Server 64 GB DDR5 RAM, 2x1 TB NVMe CPU Benchmark: 35224
Ryzen 9 5950X Server 128 GB RAM, 2x4 TB NVMe CPU Benchmark: 46045
Ryzen 9 7950X Server 128 GB DDR5 ECC, 2x2 TB NVMe CPU Benchmark: 63561
EPYC 7502P Server (128GB/1TB) 128 GB RAM, 1 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (128GB/2TB) 128 GB RAM, 2 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (128GB/4TB) 128 GB RAM, 2x2 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (256GB/1TB) 256 GB RAM, 1 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (256GB/4TB) 256 GB RAM, 2x2 TB NVMe CPU Benchmark: 48021
EPYC 9454P Server 256 GB RAM, 2x2 TB NVMe

Order Your Dedicated Server

Configure and order your ideal server configuration

Need Assistance?

⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️