Cooling Systems
```mediawiki
- Cooling Systems - Server Configuration Technical Documentation
Introduction
This document details the cooling systems employed in a high-performance server configuration, designated "Cooling Systems" for internal tracking. This configuration aims to maximize thermal management capabilities to support high-density processing and extended operational lifecycles. It goes beyond standard air cooling, incorporating liquid cooling elements for critical components. This document covers hardware specifications, performance characteristics, recommended use cases, comparisons to similar configurations, and essential maintenance considerations. This document assumes familiarity with general server hardware concepts; refer to Server Architecture for foundational information.
1. Hardware Specifications
The "Cooling Systems" configuration is built around a 2U rackmount server chassis. The core components and their specifications are detailed below.
CPU: Dual Intel Xeon Platinum 8480+ (56 cores / 112 threads per CPU, Base Frequency: 2.0 GHz, Max Turbo Frequency: 3.8 GHz, TDP: 350W). These CPUs are chosen for their high core count and inherent power density, necessitating advanced cooling. Refer to CPU Thermal Design Power for detailed explanation of TDP. RAM: 2TB DDR5 ECC Registered (8 x 256GB 5600 MHz modules). High-speed, high-capacity RAM requires adequate airflow to prevent thermal throttling. Storage: 6 x 7.68TB NVMe PCIe Gen4 x4 SSDs (U.2 interface, Read: 7000 MB/s, Write: 5500 MB/s). High-performance SSDs generate significant heat, especially under sustained load. See NVMe SSD Performance for more details. GPU (Optional): Up to 2 x NVIDIA A100 80GB PCIe Gen4 GPUs (TDP: 400W each). The inclusion of GPUs dramatically increases thermal load. GPU cooling is a priority. Motherboard: Supermicro X13DEI-N6. Designed for dual Intel Xeon Scalable processors and supports multiple PCIe Gen4 slots. Features robust power delivery and integrated IPMI 2.0 for remote management. See Server Motherboard Architecture. Power Supply: 2 x 1600W 80+ Titanium Redundant Power Supplies (Hot-Swappable). Provides ample power and redundancy. Power supply efficiency is crucial for minimizing waste heat. Reference Power Supply Units (PSUs). Network Interface: Dual 100GbE Network Adapters (Mellanox ConnectX-7). High-speed networking generates some heat, but is less significant than CPU and GPU thermal output. Chassis: 2U Rackmount Chassis with enhanced airflow design. Features multiple fan locations and liquid cooling integration points. Cooling System:
- CPU Cooling: Direct-to-Chip (D2C) Liquid Cooling - Custom copper cold plate directly mounted to each CPU, connected to a dual-loop liquid cooling system. Coolant: 50/50 mix of distilled water and propylene glycol. Pump: 2 x High-Flow PWM Pumps. Radiator: 360mm Aluminum Radiator with 3 x 120mm High-Static Pressure Fans.
- GPU Cooling (If present): Full-Cover Liquid Cooling Blocks - Custom liquid cooling blocks covering the entire GPU PCB, integrated into the same dual-loop system as the CPUs.
- RAM Cooling: Airflow-optimized RAM heatsinks with dedicated airflow from chassis fans.
- SSD Cooling: U.2 SSDs are mounted with heatsink pads for passive cooling, supplemented by chassis airflow.
- Chassis Cooling: 8 x 120mm High-Static Pressure PWM Fans strategically positioned for optimal airflow. Fan speed controlled via IPMI based on temperature sensors throughout the server. See Server Fan Control Systems.
Table: Hardware Specifications Summary
Component | Specification | |
CPU | 56 cores/112 threads per CPU| | |
RAM | 2TB DDR5 ECC Registered 5600MHz | |
Storage | 6 x 7.68TB NVMe PCIe Gen4 x4 SSDs (U.2) | |
GPU (Optional) | Up to 2 x NVIDIA A100 80GB PCIe Gen4 | |
Motherboard | Supermicro X13DEI-N6 | |
Power Supply | 2 x 1600W 80+ Titanium (Redundant) | |
Network Interface | Dual 100GbE (Mellanox ConnectX-7) | |
Chassis | 2U Rackmount | |
CPU Cooling | D2C Liquid Cooling | |
GPU Cooling | Full-Cover Liquid Cooling (optional) | |
RAM Cooling | Airflow-optimized Heatsinks | |
SSD Cooling | Heatsink Pads + Chassis Airflow |
2. Performance Characteristics
The "Cooling Systems" configuration demonstrates exceptional thermal management, allowing sustained high performance even under extreme workloads.
CPU Performance: Using the SPEC CPU 2017 benchmark suite, the server achieves the following scores (average of multiple runs):
- SPECrate2017_fp_base: 250
- SPECspeed2017_int_base: 380
These scores are significantly higher than servers relying solely on air cooling, due to the CPUs maintaining boost clocks for longer periods. See CPU Benchmarking for more details on SPEC CPU.
GPU Performance (with A100 GPUs): Measured using MLPerf inference benchmarks:
- ResNet-50 Inference: 60,000 images/second
- BERT Inference: 250,000 queries/second
The liquid cooling allows the GPUs to maintain peak clock speeds without thermal throttling, maximizing inference throughput.
Storage Performance: Measured using IOmeter:
- Sequential Read: 6800 MB/s (average)
- Sequential Write: 5200 MB/s (average)
- Random 4K Read: 750,000 IOPS (average)
- Random 4K Write: 600,000 IOPS (average)
These results demonstrate the high performance of the NVMe SSDs, sustained without thermal throttling.
Thermal Performance: Under 100% CPU and GPU load (if present), the following maximum temperatures were recorded:
- CPU: 75°C (maintained with liquid cooling)
- GPU: 70°C (maintained with liquid cooling)
- RAM: 55°C
- SSDs: 65°C
These temperatures are well within safe operating limits, ensuring long-term component reliability. See Thermal Throttling for explanation of its impact on performance.
Power Consumption: Maximum power consumption under full load: 1400W (with GPUs), 900W (without GPUs).
3. Recommended Use Cases
The "Cooling Systems" configuration is ideal for applications demanding high computational power and sustained performance.
- High-Performance Computing (HPC): Scientific simulations, weather forecasting, computational fluid dynamics. The sustained performance is critical for reducing simulation times.
- Artificial Intelligence (AI) & Machine Learning (ML): Training and inference of large AI models. The GPUs benefit significantly from the effective cooling. See AI Server Configurations.
- Data Analytics & Big Data Processing: Real-time analytics, data mining, and ETL processes. The high storage performance and sustained CPU power are essential.
- Virtualization & Cloud Computing: Hosting multiple virtual machines with demanding workloads. The stability and reliability are paramount. Refer to Server Virtualization.
- Financial Modeling & Risk Management: Complex financial simulations and real-time risk analysis.
4. Comparison with Similar Configurations
The "Cooling Systems" configuration is compared to two alternative configurations: a standard air-cooled server and a server with basic liquid cooling (CPU only).
Table: Configuration Comparison
Feature | Cooling Systems (This Configuration) | Standard Air-Cooled | |
CPU | Dual Xeon Platinum 8480+|Dual Xeon Platinum 8480+| | ||
RAM | 2TB DDR5 5600MHz | 2TB DDR5 5600MHz | |
Storage | 6 x 7.68TB NVMe | 6 x 7.68TB NVMe | |
GPU (Optional) | Up to 2 x A100 80GB | Up to 2 x A100 80GB | |
CPU Cooling | D2C Liquid Cooling | Air Cooling | |
GPU Cooling | Full-Cover Liquid Cooling (optional) | Air Cooling | |
Chassis Cooling | 8 x 120mm PWM Fans | 8 x 120mm PWM Fans | |
Max CPU Temp (°C) | 75°C | 90°C | |
Max GPU Temp (°C) (with A100) | 70°C | 95°C | |
SPECrate2017_fp_base | 250 | 200 | |
MLPerf Inference (ResNet-50) | 60,000 images/s | 50,000 images/s | |
Max Power Consumption (W) | 1400 (with GPUs) | 1200 (with GPUs) | |
Cost (Estimated) | $$$$$ | $$$ |
Analysis:
- Standard Air-Cooled: The least expensive option, but suffers from thermal throttling under sustained heavy loads, reducing overall performance. Not suitable for applications requiring constant peak performance.
- Basic Liquid Cooled (CPU Only): Offers improved CPU thermal performance compared to air cooling, but the GPUs and other components remain susceptible to thermal throttling. A good compromise for workloads primarily CPU-bound.
- Cooling Systems (This Configuration): Provides the best thermal management, allowing sustained peak performance across all components. The highest cost, but justified for demanding applications where performance is paramount. See Cost Benefit Analysis of Server Cooling.
5. Maintenance Considerations
Maintaining the "Cooling Systems" configuration requires specific attention to the liquid cooling system.
Cooling System Maintenance:
- Coolant Levels: Regularly check coolant levels in the reservoir (every 3-6 months). Top up with the recommended 50/50 distilled water/propylene glycol mix as needed.
- Leak Checks: Inspect all connections (CPU blocks, GPU blocks, radiator fittings, pump connections) for leaks at least monthly. Use leak detection fluid during initial setup and after any maintenance.
- Radiator Cleaning: Dust accumulation on the radiator fins significantly reduces cooling efficiency. Clean the radiator fins with compressed air every 3-6 months.
- Pump Maintenance: Monitor pump performance (flow rate and noise) regularly. Replace pumps every 2-3 years as a preventative measure.
- Block Cleaning: Periodically disassemble and clean the CPU and GPU water blocks to remove any buildup of deposits. (Every 1-2 years)
Power Requirements:
- The server requires dedicated 208-240V power circuits with sufficient amperage to handle the peak power draw (1400W with GPUs).
- Ensure proper grounding to prevent electrical hazards.
Airflow Management:
- Regularly clean chassis fans and vents to maintain optimal airflow.
- Ensure proper cable management to avoid obstructing airflow.
Monitoring:
- Utilize the server’s IPMI 2.0 interface to monitor temperatures, fan speeds, and pump status. Configure alerts for critical temperature thresholds. See Server Monitoring Tools.
- Implement environmental monitoring in the server room to track ambient temperature and humidity.
Component Replacement:
- When replacing components, always power down the server and disconnect it from the power source.
- Follow ESD precautions to prevent damage to sensitive electronics. Refer to Electrostatic Discharge (ESD) Prevention.
Coolant Replacement:
- Full coolant replacement is recommended every 2-3 years to maintain optimal cooling performance and prevent corrosion. Follow the manufacturer's instructions for coolant replacement.
Documentation:
- Maintain detailed records of all maintenance activities, including coolant changes, pump replacements, and leak checks.
```
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️