This is a comprehensive technical documentation article based on the requested structure and syntax requirements.

```mediawiki

Manual:Upgrading (Server Configuration Documentation)

Template:About

This configuration profile, designated "Manual:Upgrading," refers not to a fixed hardware model but to a standardized methodology applied to server platforms (often 2U or 4U rackmount chassis) that prioritize future-proofing through readily accessible, field-replaceable components. The primary design philosophy centers on maximizing component density while ensuring ease of access for maintenance and iterative performance scaling.

1. Hardware Specifications

The "Manual:Upgrading" configuration mandates adherence to specific minimum and maximum thresholds to ensure compatibility with standardized upgrade paths. This section details the baseline components assumed for an initial deployment of this profile.

1.1 Central Processing Unit (CPU)

The platform must support dual-socket configurations utilizing the Intel Xeon Scalable (Sapphire Rapids) or equivalent AMD EPYC (Genoa) families, ensuring support for PCIe Gen 5.0 and DDR5 memory standards.

CPU Baseline Specifications (Manual:Upgrading Profile v3.1)
Parameter Specification Rationale
Socket Count 2S (Dual Socket) Required for high-throughput workloads requiring significant inter-processor communication (e.g., virtualization hosts).
Supported TDP Range 150W – 350W (Sustained) Allows for high core counts while maintaining manageable thermal envelopes within standard data center cooling infrastructure. See Cooling System Requirements for details.
Maximum Cores per Socket 64 Cores (Minimum requirement for the base profile) Provides substantial parallel processing capability.
PCIe Lanes Available (Total) 160 Lanes (Minimum via CPU/Chipset aggregation) Essential for supporting multiple high-speed NVMe drives and 400GbE networking.
Instruction Set Support AVX-512 (Preferred), AMX (Accelerated Matrix Extensions) Critical for modern AI/ML inference workloads.

1.2 Memory Subsystem (RAM)

The configuration mandates DDR5 RDIMMs, utilizing the platform's maximum supported memory channels per CPU socket (typically 12 channels). The baseline profile assumes a balanced configuration favoring capacity over ultra-low latency, though the platform supports both.

Memory Configuration (Baseline)
Parameter Specification Upgrade Path Note
Memory Type DDR5 RDIMM (ECC) Supports up to DDR5-4800 MT/s natively.
Minimum Installed Capacity 512 GB Achieved via 8 x 64GB DIMMs per socket (16 total).
Maximum Supported Capacity 8 TB (Using 32 x 256GB LRDIMMs, if supported by the specific motherboard topology). Requires careful validation of motherboard slot population rules. See Memory Population Guidelines.
Memory Channel Utilization 100% (All available channels populated for baseline performance) Maximizes memory bandwidth, crucial for I/O intensive tasks.

1.3 Storage Architecture

The "Manual:Upgrading" profile is heavily focused on maximizing NVMe/PCIe storage density, typically utilizing front-accessible drive bays managed by a high-performance RAID controller or direct pass-through via a specialized PCIe switch fabric.

Primary Storage Configuration
Component Quantity (Minimum) Interface/Protocol Role
U.2/M.2 NVMe Drives 8 x 3.84 TB (Total 30.72 TB Raw) PCIe Gen 4.0/5.0 x4 Primary high-speed working storage pool.
Boot Drive (Internal) 2 x 480 GB SATA SSD SATA III (Mirrored for OS redundancy) Operating System and critical boot files.
Expansion Bays Available 16 (Total capacity depends on 2.5" vs 3.5" form factor) SAS3/SATA III/U.2 Reserved for future capacity expansion (e.g., HDD or high-density QLC NVMe).

1.4 Networking and I/O

Network connectivity must adhere to modern high-throughput standards, utilizing OCP 3.0 form factors where supported for flexibility.

Network Interface Controllers (NICs)
Port Speed Interface Type Purpose
Management Port (BMC) 1 GbE (Dedicated) RJ-45 IPMI/Redfish access.
Primary Data Port 1 100 GbE (Dual Port) QSFP28/QSFP-DD High-throughput application data transfer.
Secondary Data Port 2 25 GbE (Dual Port) SFP28 Cluster interconnect or storage access (e.g., iSCSI/RoCE).

1.5 Power and Cooling Infrastructure

The modular nature requires robust, redundant power supplies capable of handling peak transient loads during simultaneous CPU/GPU/NVMe stress.

Power and Thermal Requirements
Component Specification Note
Power Supplies (PSUs) 2 x 2000W (1+1 Redundant) 80 PLUS Titanium Efficiency Rating required.
Maximum Power Consumption (Peak) Estimated 1850W (Fully loaded, no GPU) Requires careful load balancing in the rack PDU.
Thermal Design Power (TDP Budget) 1200W (CPU/RAM only) Mandates high-efficiency airflow management.

2. Performance Characteristics

The "Manual:Upgrading" configuration is benchmarked to deliver exceptional throughput and moderate latency suitable for general-purpose enterprise workloads that require scalability. Performance metrics are highly dependent on the specific CPU generation chosen for the upgrade path.

2.1 Synthetic Benchmarks

Benchmarks focus on isolating key subsystems: CPU compute density, memory bandwidth, and I/O throughput.

2.1.1 CPU Compute (SPECrate 2017 Integer)

This metric reflects the system's ability to handle general-purpose, heavily threaded operational tasks, such as web serving or batch processing.

  • **Baseline Configuration (2 x 64-core, DDR5-4800):** Target Score Range: 1850 – 2100 SPECrate_int_base2017.
  • **Maximum Configuration (2 x 96-core, DDR5-5600):** Target Score Range: 3000+ SPECrate_int_base2017.

The performance scaling is nearly linear up to 128 cores, after which NUMA boundary effects and memory contention introduce diminishing returns, typically observed around the 160-core mark. See NUMA Architecture Impact on Performance.

2.1.2 Memory Bandwidth (STREAM Benchmark)

Memory bandwidth is a critical determinant for performance in virtualization and in-memory databases.

STREAM Benchmark Results (Aggregate Bidirectional Bandwidth)
Configuration Detail Bandwidth (GB/s) Percentage of Theoretical Max
Baseline (512GB DDR5-4800) ~650 GB/s 92%
Optimized (2TB DDR5-5600) ~880 GB/s 95%

2.2 Storage I/O Performance

The performance profile is dominated by the PCIe Gen 5 fabric capabilities.

2.2.1 Sequential Throughput

Measured using FIO against the 8-drive NVMe pool configured in a striped array (RAID 0 equivalent for peak throughput testing).

  • **Read Throughput:** Sustained 28 GB/s.
  • **Write Throughput:** Sustained 22 GB/s (accounting for write amplification on TLC/QLC drives).

2.2.2 Random IOPS

Random I/O is crucial for transactional databases and high-concurrency workloads.

  • **4K Random Read IOPS (QD32):** Exceeding 3.5 Million IOPS.
  • **4K Random Write IOPS (QD32):** Exceeding 2.8 Million IOPS.

These figures are highly dependent on the RAID controller's internal cache policy and the efficiency of the OS storage drivers.

2.3 Virtualization Density

When configured as a hypervisor host (e.g., running VMware ESXi or KVM), the configuration excels due to high core count and substantial memory capacity.

  • **Baseline Density:** Capable of reliably hosting 180-220 standard Virtual Machines (VMs) with 4 vCPUs and 8 GB RAM each, assuming moderate utilization (70% CPU readiness, 60% memory utilization).
  • **Scalability Metric:** The ratio of physical cores to maximum supported VMs is approximately 1:1.75, which is highly favorable for dense cloud environments. Refer to Virtualization Density Planning.

3. Recommended Use Cases

The flexibility and high I/O capabilities inherent in the "Manual:Upgrading" configuration make it suitable for several demanding enterprise roles where future expansion capability is a primary concern over initial cost optimization.

3.1 High-Performance Computing (HPC) Nodes

The configuration is ideal as a general-purpose compute node in a cluster environment, particularly where node homogeneity is required but component upgrades must be phased over several fiscal quarters.

  • **Requirements Met:** High memory bandwidth (for stencil computations), large number of PCIe lanes (for accelerator cards like NVIDIA H100 or specialized FPGAs), and fast local storage scratch space.

3.2 Enterprise Database Servers (OLTP/OLAP)

For systems requiring extremely fast access to large working sets, this configuration provides the necessary I/O headroom.

  • **OLTP (Online Transaction Processing):** The high random IOPS capability of the NVMe pool supports fast commit times and high transaction rates (e.g., Oracle RAC, SQL Server).
  • **OLAP (Online Analytical Processing):** The large memory capacity allows massive datasets to reside in RAM, minimizing expensive disk reads during complex queries.

3.3 Private/Hybrid Cloud Infrastructure

As a foundational element for a private cloud, the configuration offers excellent density and a clear path for scaling resources (CPU, RAM, or specialized accelerators) without replacing the entire chassis.

  • **Storage Controller Role:** Often deployed as a software-defined storage (SDS) host (e.g., Ceph OSDs or vSAN nodes), leveraging the high number of local NVMe drives for metadata and primary data tiers. See Software Defined Storage Deployment.

3.4 Advanced Virtual Desktop Infrastructure (VDI)

When paired with appropriate GPU virtualization technologies (e.g., NVIDIA vGPU), the high core count and memory capacity support dense VDI deployments for power users (e.g., CAD/Engineering workstations).

4. Comparison with Similar Configurations

To contextualize the "Manual:Upgrading" profile, it is compared against two common alternatives: the "Fixed-Spec Performance" configuration (optimized for immediate peak performance) and the "Density-Optimized Density" configuration (optimized for lowest TCO per unit volume).

4.1 Configuration Matrix Comparison

Configuration Profile Comparison
Feature Manual:Upgrading (M:U) Fixed-Spec Performance (FSP) Density-Optimized (DO)
Chassis Size 2U or 4U 1U or 2U 1U (High Density)
Max CPU TDP Support 350W 400W+ (Liquid Cooling often required) 200W (Air Cooled focus)
Storage Bays (2.5") 16 – 24 8 – 10 36+ (Using proprietary backplanes)
Upgrade Path Flexibility Excellent (Tool-less access) Moderate (Often requires partial dismantling) Poor (Dense integration)
RAM Capacity Ceiling Very High (Up to 8TB) High (Up to 6TB) Moderate (Up to 4TB)
Initial Acquisition Cost (Index) 1.0 1.25 0.85

4.2 Architectural Trade-offs

  • **M:U vs. FSP:** The M:U sacrifices the absolute highest immediate performance ceiling (e.g., cannot support 400W+ CPUs or exotic cooling) in exchange for a vastly superior long-term Total Cost of Ownership (TCO) due to component refresh cycles being easier to manage. FSP is better suited for fixed-term, high-intensity workloads where the entire unit is replaced after 3 years. See Server Lifecycle Management.
  • **M:U vs. DO:** The DO configuration maximizes the number of compute units per rack U-height, but severely limits I/O expansion and thermal headroom. M:U provides better headroom for high-power accelerators and significantly more local NVMe storage, making it superior for application-specific roles rather than pure hyper-converged infrastructure. See Rack Density Planning.

5. Maintenance Considerations

The "Manual:Upgrading" philosophy places significant emphasis on Mean Time To Repair (MTTR) and ease of component swapping. This requires adherence to specific operational protocols regarding power sequencing and thermal management.

5.1 Component Access and Hot-Swappability

The design mandates that all primary components critical to uptime must support hot-swapping or tool-less replacement.

  • **Power Supplies (PSUs):** Must be hot-swappable, leveraging the 1+1 redundancy specified in Section 1.5. PSU replacement should take less than 5 minutes without system shutdown.
  • **Fans/Cooling Modules:** Cooling assemblies are typically modular trays, often front-to-back airflow, supporting N+1 redundancy. Fan failure alerts must be granular, indicating the specific module, not just the general thermal zone. See Fan Redundancy Protocols.
  • **Drives:** All front-facing NVMe/SSD bays must support tool-less insertion/ejection mechanisms and immediate status reporting (LED indicators for rebuild/failure).

5.2 Firmware and BIOS Management

The upgrade path necessitates frequent firmware updates to maintain compatibility between new CPUs, RAM modules, and existing platform controllers.

  • **Baseboard Management Controller (BMC):** The BMC firmware must support out-of-band updates via Redfish API without requiring a system reboot, ideally supporting rolling updates if the platform utilizes dual BMCs (though this is rare in standard 2U/4U).
  • **BIOS/UEFI:** Updates must be validated against the Validated Component Matrix (VCM) before deployment, particularly when changing CPU generations, as microcode revisions can significantly impact stability, especially under heavy AVX load.

5.3 Thermal Management and Airflow

Due to the high TDP budget (up to 1200W for processing components alone), effective cooling is non-negotiable.

  • **Airflow Path:** Strict adherence to front-to-back airflow is required. Any obstruction in the front intake or rear exhaust path can lead to immediate thermal throttling (throttling thresholds typically set at 95°C junction temperature).
  • **Cooling Requirements:** The data center ambient temperature must not exceed 28°C (82.4°F) inlet temperature, even for short durations, to allow the system fans to maintain adequate static pressure across dense heatsinks. Deployment in hot-aisle containment is strongly recommended. See Data Center Thermal Guidelines.

5.4 Power Sequencing for Upgrades

When performing major upgrades (e.g., replacing both CPUs or doubling RAM capacity), the power-down and power-up sequence is critical to prevent power supply cascading failure or controller initialization errors.

1. Graceful OS shutdown. 2. Command BMC to power off system (ACPI G3 state). 3. Physically disconnect one PSU cord (for safety grounding/discharge). 4. Perform component replacement (CPU/RAM). 5. Reconnect PSU cord. 6. Power on system via BMC command. 7. Verify POST memory training completion (may take significantly longer with new population).

Failure to follow this sequence can sometimes lead to temporary errors in the Platform Management Interface (PMI) reporting.

5.5 Diagnostic Tools

The platform utilizes standardized diagnostic tools accessible via the BMC, including:

  • Remote console access (KVM over IP).
  • SEL (System Event Log) history retrieval.
  • Health monitoring for all critical sensors (voltage rails, fan speeds, temperature zones).
  • Integrated Memory Test (Pre-Boot environment).

This robust diagnostic suite minimizes the time spent troubleshooting hardware failures, directly supporting the low MTTR goal of the M:U profile. Further details on interpreting sensor logs can be found in BMC Log Interpretation Guide. ```


Intel-Based Server Configurations

Configuration Specifications Benchmark
Core i7-6700K/7700 Server 64 GB DDR4, NVMe SSD 2 x 512 GB CPU Benchmark: 8046
Core i7-8700 Server 64 GB DDR4, NVMe SSD 2x1 TB CPU Benchmark: 13124
Core i9-9900K Server 128 GB DDR4, NVMe SSD 2 x 1 TB CPU Benchmark: 49969
Core i9-13900 Server (64GB) 64 GB RAM, 2x2 TB NVMe SSD
Core i9-13900 Server (128GB) 128 GB RAM, 2x2 TB NVMe SSD
Core i5-13500 Server (64GB) 64 GB RAM, 2x500 GB NVMe SSD
Core i5-13500 Server (128GB) 128 GB RAM, 2x500 GB NVMe SSD
Core i5-13500 Workstation 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000

AMD-Based Server Configurations

Configuration Specifications Benchmark
Ryzen 5 3600 Server 64 GB RAM, 2x480 GB NVMe CPU Benchmark: 17849
Ryzen 7 7700 Server 64 GB DDR5 RAM, 2x1 TB NVMe CPU Benchmark: 35224
Ryzen 9 5950X Server 128 GB RAM, 2x4 TB NVMe CPU Benchmark: 46045
Ryzen 9 7950X Server 128 GB DDR5 ECC, 2x2 TB NVMe CPU Benchmark: 63561
EPYC 7502P Server (128GB/1TB) 128 GB RAM, 1 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (128GB/2TB) 128 GB RAM, 2 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (128GB/4TB) 128 GB RAM, 2x2 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (256GB/1TB) 256 GB RAM, 1 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (256GB/4TB) 256 GB RAM, 2x2 TB NVMe CPU Benchmark: 48021
EPYC 9454P Server 256 GB RAM, 2x2 TB NVMe

Order Your Dedicated Server

Configure and order your ideal server configuration

Need Assistance?

⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️