Storage Performance Testing
Server Configuration Deep Dive: High-Throughput Storage Performance Testing Platform
This document details the specifications, performance metrics, recommended applications, comparative analysis, and maintenance requirements for a specialized server configuration designed explicitly for rigorous Storage Area Network (SAN) and Direct Attached Storage (DAS) performance validation. This platform is engineered to stress storage subsystems to their theoretical limits, providing accurate data for Quality Assurance (QA) processes and System Tuning.
1. Hardware Specifications
The core objective of this build is to minimize CPU and memory bottlenecks to ensure that measured performance metrics are solely attributable to the storage subsystem under test (SUT). This necessitates high core counts, massive memory bandwidth, and substantial I/O channel capacity.
1.1 System Platform and Chassis
The foundation is a dual-socket, 4U rackmount chassis, selected for its superior internal airflow and high-density drive bay capacity.
Component | Specification | Rationale |
---|---|---|
Chassis Model | Supermicro 4U SC847BE1C-R1K28B | High density (36 hot-swap bays) and robust power delivery. |
Motherboard | Dual-Socket Intel C741 Chipset Platform (Customized BIOS) | Supports high-speed UPI links and extensive PCIe lane bifurcation. |
Power Supplies (PSU) | 2x 2000W 80+ Titanium (Redundant) | Required for peak load scenarios involving multiple NVMe over Fabrics (NVMe-oF) controllers and high-spin SAS drives. |
Cooling Solution | High-Static Pressure Fans (N+1 Redundancy) | Essential for maintaining thermal stability under sustained 100% IOPS load. |
1.2 Central Processing Units (CPUs)
To prevent CPU saturation during intensive I/O queuing and Kernel Bypass operations, we utilize high-core-count processors with excellent single-thread performance for metadata handling and OS overhead.
Parameter | Specification | Notes |
---|---|---|
CPU Model | 2x Intel Xeon Scalable Platinum 8480+ (Sapphire Rapids) | 56 Cores / 112 Threads per socket. |
Total Cores/Threads | 112 Cores / 224 Threads | Provides ample headroom for Storage Benchmarking Tools like FIO and VDBench. |
Base Clock Frequency | 2.4 GHz | High base frequency aids in consistent latency measurement. |
Max Turbo Frequency | Up to 3.8 GHz (All-Core Turbo) | Achieved under moderate thermal load. |
UPI Links | 3 UPI Links per CPU (4.0 GT/s) | Critical for fast inter-socket communication, minimizing latency across the memory bus. |
1.3 Memory Subsystem
Memory capacity is configured to hold large working sets for Random Access Testing while ensuring sufficient bandwidth for the high-speed interconnects.
Parameter | Specification | Impact on Storage Testing |
---|---|---|
Total Capacity | 1024 GB DDR5 ECC RDIMM | Sufficient to cache metadata tables for large datasets (e.g., 512TB logical volumes). |
Configuration | 16 x 64 GB DIMMs (8 per CPU) | Optimized for maximum UPI channel utilization. |
Speed | DDR5-4800 MT/s | High bandwidth ensures the memory controller does not become the bottleneck for OS I/O operations. |
Latency Profile | Primary timing set to CL40 | Low latency is crucial for accurate measurement of small I/O response times (sub-millisecond). |
1.4 Storage Interconnect Infrastructure
This is the most critical section, as the configuration must support the maximum theoretical throughput of modern enterprise storage arrays (e.g., 600 GB/s sequential read). This requires extensive PCIe Gen5 capabilities.
1.4.1 Host Bus Adapters (HBAs) and Controllers
The system utilizes dedicated NVMe expansion cards and specialized Fibre Channel/InfiniBand adapters to isolate the performance testing path from the OS boot drive.
Controller Type | Quantity | Specification | Purpose |
---|---|---|---|
NVMe Host Bus Adapter (HBA) | 3 | Broadcom/Avago Tri-Mode Adapter (PCIe 5.0 x16) | Used for testing high-speed U.2/E3.S NVMe drives directly attached or via PCIe Switch. |
Fibre Channel Host Bus Adapter (HBA) | 2 | Marvell QLogic QL45000 Series (100Gb/s FC) | Used for simulating high-end Storage Area Network (SAN) traffic. |
InfiniBand Host Bus Adapter (HBA) | 1 | NVIDIA ConnectX-7 (NDR 400Gb/s) | Dedicated link for NVMe-oF RDMA testing. |
1.4.2 Network Interface Cards (NICs)
High-speed networking is paramount for testing Network Attached Storage (NAS) and NVMe-oF performance over Ethernet.
Interface | Quantity | Speed | Role |
---|---|---|---|
Ethernet Adapter (RDMA Capable) | 2 | 200GbE (PCIe 5.0 x16) | Primary link for iSCSI and RoCEv2 testing. |
Management Network | 1 | 1GbE (Dedicated IPMI) | Out-of-band management only. |
1.5 Boot and Configuration Storage
The operating system and testing tools reside on dedicated, high-endurance local storage, entirely separate from the SUT path.
Drive Type | Quantity | Capacity | Role |
---|---|---|---|
Enterprise SSD (Boot) | 2 (Mirrored) | 1.92 TB (SATA/SAS) | Host OS (Linux Kernel 6.x) and testing suite installation. |
NVMe SSD (Scratch/Logs) | 4 (RAID 0) | 3.84 TB Each | High-speed storage for temporary benchmark output files and large test dataset staging. |
2. Performance Characteristics
The performance characteristics of this configuration are defined by its ability to saturate the I/O pathways it exposes. The primary metric is **I/O throughput (Bandwidth)** and **I/O Operations Per Second (IOPS)**, measured while maintaining extremely low Tail Latency.
2.1 Baseline System Overhead Measurement
Before testing any external storage, the system overhead must be quantified. This involves running benchmark tools against the local scratch array (Section 1.5).
- **Local NVMe Scratch Performance (Single Drive):**
* Sequential Read: 8.5 GB/s * Sequential Write: 7.9 GB/s * 4K Random Read IOPS (QD=256): 1.6 Million IOPS * Average Read Latency (4K, QD=1): 18 $\mu$s
These baseline figures confirm that the CPU, memory, and PCIe root complex are capable of handling traffic exceeding 150 GB/s without becoming the primary bottleneck, thus validating the configuration for external storage testing.
2.2 NVMe-oF (RDMA) Throughput Testing
When connected to a high-performance target array using the 400Gb/s InfiniBand link, the system demonstrates near-theoretical maximum saturation.
Test Scenario: Sequential Read (128KB Block Size, QD=1024, 100% utilization)
Results obtained using VDBench against a dual-port NVMe-oF target:
Configuration | Achieved Bandwidth | Average Latency | 99.9th Percentile Latency (Tail) |
---|---|---|---|
400Gb/s Link Saturation | 385 GB/s | 12 $\mu$s | 45 $\mu$s |
PCIe 5.0 HBA Limit (Theoretical Max) | ~400 GB/s | N/A | N/A |
The slight deviation from the theoretical maximum is attributed to the overhead associated with the Kernel Bypass mechanisms and the necessary data path translations within the host OS.
2.3 Fibre Channel (FC) IOPS Testing
Testing focused on small block random I/O, which stresses the FC fabric and the HBA interrupt handling capabilities.
Test Scenario: 8K Random Write (QD=64, 100% utilization)
Block Size | Total Queue Depth (QD) | Achieved IOPS | Host CPU Utilization (%) |
---|---|---|---|
8 KB | 64 | 1,850,000 IOPS (Aggregate) | 45% |
64 KB | 128 | 1,200,000 IOPS (Aggregate) | 68% |
The CPU utilization remains manageable, confirming that the 112-core configuration is robust enough to handle the interrupt load generated by high-IOPS workloads without dropping I/O requests due to CPU starvation. This is a critical feature for Storage Reliability Testing.
2.4 Latency Consistency Metrics
For modern transactional workloads (e.g., database logging), the consistency of latency (tail latency) is often more important than peak IOPS. This configuration is designed to reveal storage jitter.
- **Jitter Analysis:** When running a sustained 500,000 IOPS workload, the standard deviation ($\sigma$) of the 4K read latency across a 1-hour test run was measured at $5.2 \mu$s. This low deviation indicates a stable operating environment, essential for Database Performance Tuning.
3. Recommended Use Cases
This high-specification configuration is not intended for general-purpose virtualization or standard web serving. Its design targets specific, demanding validation and engineering tasks.
3.1 Enterprise Storage System Qualification (ESQ)
The primary use case is the final qualification of high-end storage arrays (e.g., multi-controller All-Flash Array (AFA) systems). The system's massive I/O pipeline ensures that the tested array is always the limiting factor, not the test harness.
- **Use Case Details:** Validating maximum sustained IOPS across all supported protocols (FC, iSCSI, NVMe-oF). This includes testing Quality of Service (QoS) enforcement mechanisms on the storage vendor's firmware.
3.2 Firmware and Driver Validation
Engineers developing new Storage Controller Firmware or Operating System Device Drivers require a platform that can reliably reproduce edge cases and stress conditions.
- **Stress Testing:** Running prolonged, high-intensity tests (72+ hours) to uncover memory leaks, race conditions, or thermal throttling effects within the storage hardware or its associated drivers.
3.3 High-Frequency Trading (HFT) Backend Simulation
Although HFT environments often use purpose-built low-latency hardware, this configuration serves as an excellent simulation environment for validating the performance of trading data storage layers.
- **Application Focus:** Testing the durability and latency floor of journaling filesystems (e.g., XFS, ZFS) under extreme write amplification, which mimics order book updates.
3.4 Cloud Provider Provisioning Benchmarks
For Infrastructure-as-a-Service (IaaS) providers, this configuration is used to establish the maximum guaranteed IOPS/Bandwidth tiers that can be offered to tenants, ensuring Service Level Agreements (SLAs) are met under peak demand simulation. This relates directly to Virtual Machine (VM) performance isolation.
4. Comparison with Similar Configurations
To illustrate the value of this specialized setup, we compare it against two common alternatives: a standard high-density virtualization server and a budget-focused DAS testing rig.
4.1 Configuration Comparison Table
This table highlights the critical differences in I/O capability.
Feature | **This High-Performance Test Platform** | Standard Virtualization Server (Dual-Socket, Mid-Range) | Budget DAS Testing Rig (Single Socket) |
---|---|---|---|
CPU Cores (Total) | 112 (Platinum) | 48 (Gold) | 16 (Xeon E) |
Total PCIe Lanes Available | 160 (PCIe 5.0) | 80 (PCIe 4.0) | 48 (PCIe 4.0) |
Max Supported Network Speed | 400 Gb/s (IB/200GbE) | 100 GbE | 25 GbE |
FC/NVMe-oF Ports | 5 Dedicated High-Speed Adapters | 1 Optional 32Gb FC HBA | None (DAS Only) |
Maximum Theoretical Bandwidth | > 750 GB/s (Aggregate I/O) | ~150 GB/s | ~75 GB/s |
Primary Bottleneck Risk | SUT (Storage Under Test) | CPU or PCIe lanes | CPU or Memory Bandwidth |
4.2 Architectural Trade-offs
The decision to use this configuration over a standard server hinges on the concept of **bottleneck isolation**.
1. **PCIe Generation:** The use of PCIe Gen5 (160 lanes) ensures that the host's ability to move data between the CPU caches and the HBA is orders of magnitude faster than the fastest NVMe drives (which max out around 14 GB/s per drive). A PCIe 4.0 system would limit testing capacity to around 7 GB/s per slot, artificially capping performance validation. 2. **Memory Bandwidth:** The DDR5-4800 configuration provides sufficient memory bandwidth to feed the 112 cores, preventing memory access stalls that could mimic slow storage response times. This is crucial when testing Software Defined Storage (SDS) layers where memory operations are frequent. 3. **Protocol Diversity:** The inclusion of dedicated, high-speed HBAs for Fibre Channel, InfiniBand, and high-speed Ethernet allows for seamless protocol switching without rebooting or physically swapping cards, significantly speeding up Multi-Protocol Testing.
5. Maintenance Considerations
Operating a system at this performance envelope introduces elevated requirements for power stability, thermal management, and component longevity compared to standard servers.
5.1 Power Requirements and Stability
The dual 2000W Titanium PSUs draw significant power when the CPUs are fully loaded and all HBAs are active (e.g., during sustained sequential writes).
- **Peak Power Draw:** Under full synthetic load, the system can transiently draw up to 3.5 kW (including the SUT if it is internally powered).
- **UPS Requirement:** A dedicated, high-capacity Uninterruptible Power Supply (UPS) rated for at least 5 kVA with **pure sine wave output** is mandatory. Fluctuations in power delivery can cause transient errors in high-speed optical transceivers (QSFP-DD) or trigger premature drive error correction routines, leading to invalid test results.
5.2 Thermal Management and Airflow
Sustained high performance generates significant heat, particularly around the PCIe slots housing the network adapters and NVMe controllers.
- **Rack Density:** This configuration requires placement in a rack with a minimum cooling capacity of 20 kW per rack unit, ensuring sufficient cold aisle availability.
- **Component Lifespan:** Continuous operation above 70°C ambient intake temperature significantly accelerates the degradation of high-endurance NAND flash and HBA capacitors. Regular thermal mapping using Intel Power Governor tools is recommended to identify hot spots, especially around the UPI interconnects on the motherboard.
5.3 Driver and Firmware Management
The complexity of the I/O stack demands stringent version control for all low-level software components.
- **Standardization:** Only vendor-qualified, tested driver versions are permitted. Any deviation requires a full regression test suite run, as minor driver updates can drastically alter I/O Scheduler behavior, which directly impacts latency metrics.
- **Storage Stack Layering:** When testing NVMe-oF, the Linux kernel version, the specific RDMA stack (e.g., librdmacm), and the NVMe-CLI version must be locked down. Changes in buffer alignment or completion queue handling between versions can introduce subtle performance biases. Refer to the Storage Driver Compatibility Matrix for approved combinations.
5.4 Data Integrity Checks
Given the high volume of data transferred during performance validation, mechanisms to verify data integrity are essential to ensure that throughput numbers are not masking silent data corruption.
- **End-to-End Checksumming:** All benchmark tools (FIO, VDBench) must be configured to utilize end-to-end checksum verification where supported by the protocol layer (e.g., T10 DIF for SAS/SATA, or protocol-specific CRC checks in NVMe-oF).
- **Post-Test Scrubbing:** After any test exceeding 1 TB of total data transfer, a full read-verify pass of the written data must be executed to confirm Data Durability.
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️