Spark
Technical Documentation: Server Configuration "Spark"
This document details the technical specifications, performance profile, deployment recommendations, comparative analysis, and maintenance requirements for the server configuration designated "Spark." The Spark configuration is engineered for high-throughput, low-latency data processing tasks requiring significant computational density and fast parallel I/O capabilities, positioning it as a flagship offering in the mid-to-high-end enterprise sector.
1. Hardware Specifications
The Spark configuration is built upon a dual-socket motherboard architecture optimized for next-generation Intel Xeon Scalable (Sapphire Rapids) families, prioritizing core count density and high-speed memory bandwidth.
1.1 Core Processing Unit (CPU)
The configuration mandates specific CPU SKUs to ensure consistent performance targets.
Parameter | Specification |
---|---|
Primary Processor Model | 2 x Intel Xeon Gold 6448Y (32 Cores, 64 Threads each) |
Base Clock Frequency | 2.5 GHz |
Max Turbo Frequency (Single Core) | 3.9 GHz |
Total Physical Cores | 64 Cores |
Total Logical Processors | 128 Threads |
L3 Cache per CPU | 60 MB (Intel Smart Cache) |
Total L3 Cache | 120 MB |
TDP (Thermal Design Power) | 205W per socket |
Instruction Sets Supported | AVX-512, VNNI, AMX (Advanced Matrix Extensions) |
The inclusion of Advanced Matrix Extensions (AMX) is critical for accelerating deep learning inference workloads, a key driver for the Spark configuration's design philosophy. The high core count minimizes context switching overhead in heavily threaded applications like virtualization hosts or large-scale in-memory databases.
1.2 Memory Subsystem
The Spark configuration leverages the DDR5 standard, offering significantly higher bandwidth and lower latency compared to previous DDR4 implementations, crucial for feeding the numerous CPU cores efficiently.
Parameter | Specification |
---|---|
Memory Type | DDR5 ECC Registered DIMM (RDIMM) |
Total DIMM Slots | 32 (16 per CPU channel) |
Configured Capacity | 1024 GB (1TB) |
DIMM Speed / Data Rate | 4800 MT/s (JEDEC standard for current CPU generation) |
Configuration Layout | 32 x 32 GB DIMMs, optimally balanced across all memory channels (8 channels per CPU) |
Maximum Supported Capacity | 4 TB (using 128 GB DIMMs, pending vendor qualification) |
Memory Bandwidth (Theoretical Peak) | Approximately 819.2 GB/s (Bi-directional) |
Optimal memory population ensures that all Memory Channels are utilized symmetrically, preventing memory bottlenecks often seen in under-populated dual-socket systems. The 1TB baseline is chosen to accommodate large datasets resident in memory for rapid access, aligning with In-Memory Computing paradigms.
1.3 Storage Architecture
The storage subsystem prioritizes speed and redundancy, employing a hybrid approach suitable for tiered access patterns.
1.3.1 Boot and System Storage
A pair of small-form-factor NVMe drives configured in a hardware RAID 1 array provides a resilient boot volume for the operating system and hypervisor.
- Drives: 2 x 960GB Enterprise NVMe SSD (U.2 Interface)
- RAID Controller: Integrated or dedicated PCIe Gen5 RAID adapter supporting NVMe passthrough/mirroring.
1.3.2 Primary Data Storage (Compute Tier)
The primary storage pool utilizes high-speed, high-endurance PCIe 4.0/5.0 NVMe SSDs directly attached via the motherboard's onboard M.2 slots or through specialized HBA/RAID cards supporting direct-attached NVMe.
Parameter | Specification |
---|---|
Drive Type | Enterprise NVMe SSD (AIC or U.2 Form Factor) |
Capacity per Drive | 7.68 TB |
Total Drives | 8 Drives |
Total Raw Capacity | 61.44 TB |
Array Configuration | RAID 10 (Software or Hardware Dependent) |
Effective Usable Capacity | ~30.72 TB (Post-RAID 10 Overhead) |
Target Sequential Read Speed (Aggregate) | > 25 GB/s |
Target IOPS (4K Random Read) | > 10 Million IOPS |
This configuration emphasizes IOPS and low latency over raw capacity, distinguishing it from archival or backup server configurations. NVMe over Fabrics (NVMe-oF) support is enabled via the network interface cards for external storage expansion, though the internal array serves as the primary working set.
1.4 Networking Interface
High-speed, low-latency networking is non-negotiable for data-intensive tasks.
- Primary Interconnect (Data/Compute): 2 x 100 Gigabit Ethernet (100GbE) ports, utilizing RDMA over Converged Ethernet (RoCE) capabilities for near-memory access in clustered environments.
- Management Interface (OOB): 1 x 1GbE dedicated port for Baseboard Management Controller (BMC) access (IPMI/Redfish).
- Expansion Slots: 4 x PCIe 5.0 x16 slots available for specialized accelerators or additional high-speed networking cards (e.g., InfiniBand or specialized GPU interconnects).
1.5 Chassis and Power
The Spark configuration is housed in a 2U rackmount chassis designed for high airflow and dense component integration.
- Chassis Form Factor: 2U Rackmount.
- Power Supplies: Dual redundant 2400W Platinum/Titanium rated PSUs.
- Power Redundancy: N+1 configured for full operational uptime during PSU failure.
- Cooling: High-static-pressure fans optimized for dense server stacks. Ambient operating temperature specification: 18°C to 27°C (64.4°F to 80.6°F).
2. Performance Characteristics
The Spark configuration is benchmarked against industry standards to validate its suitability for demanding workloads. Performance is dominated by the high core count coupled with the rapid data movement enabled by DDR5 and NVMe Gen5 storage interfaces.
2.1 Synthetic Benchmarks
2.1.1 CPU Throughput (SPECrate 2017 Integer)
The dense core count provides excellent throughput scaling for highly parallelized codebases.
Metric | Result (Score) |
---|---|
SPECrate 2017 Integer Base | ~1150 |
SPECrate 2017 Integer Peak | ~1280 |
- Note: Results are based on aggregated data for similar dual-socket SKUs; actual results depend on BIOS tuning and memory interleaving configuration.
2.1.2 Memory Bandwidth Testing
Testing confirms the efficiency of the DDR5 implementation.
- AIDA64 Memory Read Test: Measured aggregate bandwidth consistently exceeds 750 GB/s utilizing optimized memory access patterns (e.g., streaming loads).
- Latency: Measured average memory latency (CL to first data block) is below 70 nanoseconds (ns) under standard load conditions. This low latency is crucial for database transaction processing.
2.2 Workload-Specific Benchmarks
2.2.1 Database Transaction Processing (OLTP)
For transactional workloads, the combination of fast storage IOPS and high core count delivers superior transaction rates.
- TPC-C (10,000 Virtual Users): Target sustained throughput consistently exceeds 600,000 transactions per minute (tpmC). The storage subsystem (RAID 10 NVMe) prevents I/O queuing delays that typically bottleneck older SATA/SAS SSD arrays. Database Performance Analysis shows that 95% of transactions commit within 5ms.
2.2.2 Big Data Analytics (Spark/Hadoop)
When configured as a worker node in a distributed Apache Spark cluster, the Spark configuration excels in iterative calculations due to its large on-board cache (120MB L3) and fast memory access.
- TPC-DS 10TB Scale Factor (Query Set 99): Average query execution time is reduced by approximately 35% compared to the previous generation (Ice Lake equivalent) server using DDR4 memory, primarily attributed to the DDR5 bandwidth increase and AMX acceleration for certain mathematical kernels.
2.2.3 Virtualization Density
As a Virtual Machine (VM) host, the system density is maximized.
- VM Density Test (vSphere 8.0): Capable of stably hosting 150 standard 8-core/16GB RAM VMs (total utilization 120 cores, 2.4TB RAM), demonstrating strong CPU oversubscription capacity while maintaining acceptable Quality of Service (QoS) for interactive workloads.
2.3 Thermal Throttling Analysis
Due to the 205W TDP per CPU, thermal management is critical. Under sustained, all-core load (e.g., Prime95 or heavy transcoding), the system maintains CPU frequencies within 5% of the advertised Max Turbo Frequency (3.7 GHz sustained) provided ambient inlet temperatures remain below 25°C. Exceeding this threshold results in minor frequency throttling (down to 3.5 GHz sustained) to maintain component reliability. Thermal Management in Data Centers protocols must be strictly followed.
3. Recommended Use Cases
The Spark configuration is purpose-built for scenarios demanding high computational density, rapid data access, and robust I/O performance within a compact 2U footprint.
3.1 High-Performance Database Servers
The configuration is ideally suited for hosting mission-critical, high-transaction databases, particularly those leveraging in-memory features.
- **In-Memory Databases (e.g., SAP HANA, Redis Cache):** The 1TB of fast DDR5 memory allows for substantial dataset residency, minimizing disk I/O latency for lookups and writes.
- **SQL Server / Oracle:** Excellent performance for mixed OLTP and light OLAP workloads due to balanced CPU/Memory/Storage ratios.
3.2 Distributed Computing and HPC Nodes
The high core count and excellent network interconnectivity make it a superior choice for cluster deployments.
- **Apache Spark/MapReduce Workers:** Optimized for iterative algorithms that benefit from large L3 caches and fast access to local scratch space (the internal NVMe array).
- **Container Orchestration Hosts (Kubernetes/OpenShift):** Can host hundreds of high-density microservices containers, leveraging the 128 logical processors efficiently. Containerization Best Practices emphasize uniform node performance, which Spark provides.
3.3 Critical Virtualization Platforms
When high consolidation ratios are required without sacrificing the performance of critical guest operating systems.
- **VDI Infrastructure Brokers:** Capable of serving numerous virtual desktops where interactive response time is paramount.
- **Mixed Workload Hypervisors:** Running both production application servers and development/testing environments on the same physical host efficiently.
3.4 AI/ML Inference Acceleration
While the primary configuration does not mandate dedicated GPUs, the presence of Advanced Matrix Extensions (AMX) allows the CPU to handle complex matrix multiplication tasks efficiently for inference workloads that do not justify the cost or power draw of full-scale GPU accelerators. This is particularly relevant for real-time recommendation engines or low-volume model serving.
4. Comparison with Similar Configurations
To illustrate the positioning of the Spark configuration, it is compared against two common alternatives: the "Atlas" configuration (focused on maximum storage density) and the "Pulsar" configuration (focused on extreme single-thread performance and accelerator density).
4.1 Configuration Overview Table
Feature | Spark (Target Configuration) | Atlas (Storage Density Focus) | Pulsar (Accelerator Focus) |
---|---|---|---|
Chassis Size | 2U | 4U | 2U |
CPU Target | Dual Xeon Gold (High Core Count) | Dual Xeon Bronze/Silver (Lower TDP) | Dual Xeon Platinum (Highest Core/Clock Speed) |
Total Cores (Example) | 64 Cores | 48 Cores | 56 Cores |
System RAM (Baseline) | 1 TB DDR5 | 512 GB DDR5 | 1 TB DDR5 |
Internal NVMe Storage | 61.44 TB (RAID 10) | 300 TB (JBOD/Software RAID) | 15.36 TB (RAID 1) |
PCIe Slots | 4 x PCIe 5.0 x16 | 6 x PCIe 5.0 x8 (optimized for HBAs) | 8 x PCIe 5.0 x16 (optimized for GPUs) |
Primary Strength | Balanced Throughput & Latency | Raw Capacity & Cost Efficiency | Peak Compute Density (GPU/FPGA) |
4.2 Comparative Analysis
- **Versus Atlas (Storage Density):** Spark sacrifices raw raw disk capacity (300TB vs 30TB usable) and accepts higher component cost for significantly faster storage access (NVMe vs. high-capacity SAS SSDs) and greater CPU compute power. Atlas is better suited for archival storage tiers or large data lakes where high IOPS are not the primary bottleneck. Storage Tiering Strategy dictates the choice here.
- **Versus Pulsar (Accelerator Focus):** Pulsar uses higher-tier CPUs that might offer slightly better single-thread performance or higher clock speeds, but crucially, Pulsar dedicates most of its PCIe lanes and thermal budget to accelerators (e.g., 4x NVIDIA H100s). Spark is the superior choice when the workload is CPU-bound or requires massive amounts of fast local memory *without* requiring massive floating-point acceleration from GPUs. GPU Computing Integration is the defining factor for Pulsar deployment.
The Spark configuration occupies the sweet spot for general-purpose enterprise workloads requiring modernization beyond standard rack servers, offering a significant leap in I/O and memory performance over previous generations without the specialized infrastructure required by GPU-heavy Pulsar systems. Server Lifecycle Management suggests Spark has a longer viable lifespan for general compute tasks than accelerator-dependent systems.
5. Maintenance Considerations
Deploying the Spark configuration requires adherence to specific operational protocols related to power density, thermal management, and complex component sourcing.
5.1 Power Requirements and Density
The dual 205W CPUs, combined with high-speed DDR5 DIMMs and multiple high-power NVMe drives, result in a high power draw under peak load.
- **Total System Power Draw (Peak):** Estimated at 1,200W to 1,500W, depending on the utilization of the NVMe array.
- **Rack Density Planning:** Standard 1U servers often draw 500W-700W. Deploying Spark mandates higher PDU capacity (minimum 15A circuit per rack unit, depending on PDU configuration) and careful load balancing across the Power Distribution Units (PDUs) to prevent tripping circuits or overloading power zones. Data Center Power Provisioning must account for this increased density.
5.2 Cooling and Airflow
The 2U form factor combined with high TDP components necessitates superior cooling infrastructure compared to lower-density servers.
- **Inlet Air Temperature:** Maintaining the inlet air temperature below 24°C is strongly recommended to prevent the thermal throttling discussed in Section 2.3.
- **Airflow Management:** Proper blanking panels and airflow directionality within the rack are essential. The server relies on high static pressure fans; obstructions directly in front of or behind the unit significantly degrade cooling efficiency. Rack Airflow Best Practices are mandatory.
5.3 Firmware and Component Management
The reliance on advanced technologies like DDR5 and PCIe 5.0 requires stringent firmware management.
- **BIOS/UEFI Updates:** Regular updates are crucial, particularly for memory retraining algorithms and PCIe lane allocation stability, as early firmware versions sometimes exhibit instability under the high memory bandwidth demands of this configuration.
- **Storage Controller Firmware:** NVMe drive firmware must be synchronized with the RAID/HBA controller firmware to ensure optimal wear leveling and performance consistency. Failure to update can lead to premature drive failure or performance degradation. Storage Reliability Engineering focuses heavily on firmware matching.
- **Component Sourcing:** Due to the tight integration of high-speed components, using only vendor-qualified components (especially DIMMs and NVMe drives) is non-negotiable. Substituting components can lead to instability or failure to boot due to timing mismatch on the high-speed memory bus. Server Component Qualification Process must be strictly followed.
5.4 Operating System and Driver Support
The Spark configuration requires modern operating systems and hypervisors that fully support the instruction sets and hardware features.
- **OS Requirements:** Linux distributions (e.g., RHEL 9+, Ubuntu 22.04+) or Windows Server 2022 are required to properly leverage AMX and utilize the full throughput of the 100GbE adapters with RoCE support. Older OS versions will result in significant performance degradation due to missing driver optimizations. Operating System Hardware Abstraction Layers must be current.
- **Virtualization Layers:** Hypervisors must support PCIe 5.0 passthrough mechanisms efficiently if direct device access is required by guest VMs. Hardware Assisted Virtualization features must be enabled in the BIOS.
5.5 Redundancy and Monitoring
- **Hardware Monitoring:** Comprehensive utilization of the Redfish API or equivalent IPMI interface is required for proactive monitoring of CPU temperatures, fan speeds, and PSU health. Alert thresholds should be set aggressively, particularly for the storage array, where the failure of a single drive in the RAID 10 configuration immediately impacts performance integrity.
- **Network Redundancy:** The dual 100GbE ports should be configured using Link Aggregation Control Protocol (LACP) or active/passive failover, depending on the switch fabric capabilities, to ensure data plane resilience. Network Resiliency Protocols must be implemented at the switch layer.
The Spark configuration, while powerful, demands a higher level of operational maturity in power, cooling, and firmware management than standard compute nodes. Successful deployment hinges on disciplined adherence to vendor guidelines for high-density, high-performance hardware. Server Hardware Lifecycle Management plans should allocate sufficient budget for specialized cooling infrastructure upgrades if moving from legacy server generations.
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️