Network infrastructure
Server Configuration Deep Dive: High-Throughput Network Infrastructure Platform (Model: NET-INFRA-X9000)
This document provides comprehensive technical specifications, performance analysis, and operational guidelines for the **NET-INFRA-X9000**, a server platform specifically engineered for demanding, high-throughput network infrastructure roles such as load balancing, deep packet inspection (DPI), software-defined networking (SDN) controllers, and high-speed firewall operations.
1. Hardware Specifications
The NET-INFRA-X9000 is built upon a 2U rackmount chassis, prioritizing dense PCIe lanes, high-speed interconnects, and robust memory capacity necessary for complex network state tables and flow tracking.
1.1 Core Processing Unit (CPU)
The platform utilizes dual-socket processing, balancing core count for parallel processing tasks (like flow distribution) with high single-thread performance crucial for cryptographic acceleration and protocol stack overhead.
Parameter | Specification | Rationale | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Socket Configuration | Dual Socket (2P) | Maximizes PCIe lane availability and memory bandwidth. | CPU Model | 2x Intel Xeon Scalable Platinum 8592+ (60 Cores, 120 Threads per CPU) | High core count (120 total physical cores) for massive parallelism in packet processing. | Base Frequency | 2.1 GHz | Ensures sustained performance under heavy load. | Max Turbo Frequency (Single Core) | Up to 4.0 GHz | Critical for latency-sensitive tasks like initial connection setup. | L3 Cache Size | 112.5 MB per CPU (225 MB Total) | Large cache minimizes memory access latency for flow lookups. | TDP (Thermal Design Power) | 350W per CPU | Requires specialized cooling infrastructure (see Section 5). | Instruction Sets Supported | AVX-512, VNNI, AMX | Essential for acceleration in modern cryptography and AI-driven network analysis. |
1.2 Memory Subsystem
Network infrastructure tasks, especially those involving stateful inspection (e.g., stateful firewalls) or large routing tables, demand substantial, low-latency memory.
The system supports up to 8 TB of DDR5 memory across 32 DIMM slots (16 per CPU). We specify the high-density, performance-optimized configuration.
Parameter | Specification | Notes |
---|---|---|
Total Capacity | 2048 GB (2 TB) | Achieved using 64GB DDR5-5600 ECC RDIMMs. |
Configuration | 32 x 64 GB DIMMs | Populating all available slots for maximum bandwidth utilization. |
Memory Type | DDR5 ECC RDIMM | Error Correction is mandatory for infrastructure stability. |
Memory Speed | 5600 MT/s | Optimized for peak bandwidth performance. |
Memory Channels | 8 Channels per CPU (16 Total) | Maximizes memory throughput required by high-speed NICs. |
Maximum Theoretical Bandwidth | ~1.4 TB/s (Aggregate) | Crucial for feeding the high-speed network interfaces. |
For reference on memory management in virtualized environments, see Virtual Memory Management.
1.3 Storage Subsystem
Storage in this configuration is optimized for high-speed logging, telemetry data capture, and rapid boot/configuration persistence, rather than bulk data serving. NVMe SSDs are prioritized for low I/O latency.
Type | Quantity | Capacity/Speed | Role |
---|---|---|---|
Boot/OS Drive | 2x M.2 NVMe (Mirrored) | 1.92 TB each (PCIe Gen4 x4) | OS, Management Software, Hypervisor Boot. RAID 1 Mirroring. |
System Storage (Logs/Telemetry) | 4x U.2 NVMe SSDs | 7.68 TB each (PCIe Gen5 x4) | High-speed capture of flow records, security events, and monitoring statistics. |
Storage Controller | Broadcom MegaRAID SAS 9690W-16i (or equivalent integrated solution) | Supports PCIe Gen5 passthrough for maximum NVMe performance. |
The system utilizes a dedicated Storage Area Network (SAN) for persistent application data, meaning the internal storage is reserved strictly for operational data requiring low latency.
1.4 Networking Interfaces and Expansion
This is the most critical component of the NET-INFRA-X9000. The platform is designed to support multiple high-speed interfaces, often requiring direct hardware offload capabilities. The 2U chassis provides ample PCIe slots (10 total full-height, full-length slots).
Slot Location | PCIe Generation/Lanes | Adapter Installed | Function |
---|---|---|---|
Slot 1 (Primary) | PCIe 5.0 x16 | Mellanox ConnectX-7 Dual Port 400GbE NIC | Uplink / Core Network Connection (Data Plane 1) |
Slot 2 (Secondary) | PCIe 5.0 x16 | Mellanox ConnectX-7 Dual Port 400GbE NIC | Management/Out-of-Band (OOB) Connection (Data Plane 2) |
Slot 3 (Expansion 1) | PCIe 5.0 x16 | DPDK Accelerator Card (e.g., FPGA/SmartNIC) | Packet processing acceleration / Offload Engine. |
Slot 4 (Expansion 2) | PCIe 5.0 x8 [Note 1] | Intel E810-XXV (25GbE Quad Port) | Management Network / Internal Service Mesh Connections. |
Slot 5 (Expansion 3) | PCIe 5.0 x16 | Dedicated Crypto Accelerator Card (e.g., HSM or specialized ASIC) | TLS/IPsec Offload. |
Remaining Slots | PCIe 5.0 x8/x16 | Reserved for future expansion or specialized hardware (e.g., DPDK targeting). |
- Note 1: Slot 4 is electrically limited to x8 due to chipset topology, but is sufficient for 25GbE links.*
The selection of 400GbE interfaces is necessary to prevent bottlenecks when processing massive flows from spine layers in modern leaf-spine topologies.
1.5 Management Architecture
The system incorporates redundant Baseboard Management Controllers (BMCs) compliant with the IPMI 2.0 specification, or preferably, Redfish API compatibility for modern orchestration.
- **BMC Model:** Dual Redundant ASPEED AST2600 or equivalent.
- **Dedicated Management Port:** 1GbE (Shared with Data Plane 2 NIC for OOB access).
- **Features:** Remote KVM, virtual media, power cycling, and sensor monitoring compliant with SNMP v3.
2. Performance Characteristics
The NET-INFRA-X9000 is benchmarked not on raw compute FLOPS, but on its ability to sustain high packet rates (PPS) and low latency under maximum load.
2.1 Network Throughput Benchmarks
Testing was conducted using the TRex traffic generator, focusing on Layer 3 forwarding performance using a standardized 64-byte packet size (minimum size for maximum PPS).
Test Scenario | Configuration Used | Measured Throughput (Millions of PPS) | Latency (99th Percentile) |
---|---|---|---|
Baseline Forwarding (CPU Only) | 120 Cores Active, No Offload | 58.5 Mpps | 1.8 µs |
Hardware Offload (X7 NICs) | Full 800 Gbps (400GbE x 2) | 148.8 Mpps | 0.9 µs |
Stateful Firewall (512k Flows) | CPU + NIC Offload + 1TB RAM utilized for state tables | 135.2 Mpps | 1.1 µs |
IPsec Tunnelling (1024-bit Keys) | Utilizing dedicated Crypto Accelerator Card | 120.1 Mpps | 1.5 µs |
These figures demonstrate that the system can sustain near-line-rate performance at 400GbE aggregation, provided that hardware acceleration features (like those provided by the ConnectX-7 or specialized accelerators) are utilized. The CPU alone struggles to reach 60 Mpps due to the overhead of kernel processing and context switching inherent in traditional networking stacks.
2.2 CPU Utilization and Scaling
When running intensive network functions (e.g., complex BGP route calculation, NAT translation), performance scales nearly linearly up to 80% CPU utilization. Beyond this point, performance gains diminish due to contention for shared resources, particularly the UPI links between the two CPUs and the overall PCIe fabric bandwidth.
- **Optimal Processing Zone:** 60%–80% utilization across all cores.
- **Bottleneck Identification:** In tests involving deep packet inspection (DPI) using regular expression matching, the primary bottleneck shifts from memory bandwidth to the raw instruction throughput of the AVX-512 units, supporting the choice of the Platinum series CPUs. For more context on CPU scaling, review CPU Scaling and NUMA Architecture.
2.3 Power Consumption Profile
Due to the high-TDP CPUs and multiple high-speed NICs, power management is critical.
- **Idle Power Consumption:** ~350W (with all NICs active but idle).
- **Peak Load Power Consumption:** ~1450W (Sustained maximum load across all components).
This necessitates the use of high-efficiency Power Supply Units (PSUs) rated for 80 PLUS Titanium certification.
3. Recommended Use Cases
The NET-INFRA-X9000 is over-provisioned for standard virtualization hosts or web serving but is perfectly suited for critical infrastructure roles where uptime, low latency, and massive bandwidth throughput are non-negotiable.
3.1 High-Performance Load Balancing
This platform excels as a primary load balancer tier, capable of managing millions of concurrent connections (e.g., HAProxy, NGINX Plus configured for TCP/L4 or basic L7 balancing).
- **Key Requirement Met:** The large L3 cache and high core count allow the system to maintain extensive connection state tables without excessive RAM access latency. The 400GbE interfaces allow aggregation from numerous downstream servers.
3.2 Software-Defined Networking (SDN) Controllers
As a centralized control plane element (e.g., running OpenDaylight or ONOS), the platform provides the necessary compute density to manage tens of thousands of network endpoints and rapidly process topology updates.
- **Key Requirement Met:** High memory capacity (2TB) is essential for storing vast, dynamic network topology graphs and policy databases.
3.3 High-Speed Intrusion Detection and Prevention Systems (IDPS/IPS)
For environments requiring line-rate security inspection on 100GbE or 200GbE links, this hardware is mandatory. The ability to utilize dedicated hardware acceleration cards (Slot 3) for flow classification means that signature matching does not consume precious CPU cycles.
- **Key Requirement Met:** The platform supports full packet capture to high-speed NVMe storage (Section 1.3) for forensic analysis without dropping packets during high-burst events. See also Network Security Monitoring Best Practices.
3.4 Telemetry Aggregation and Flow Analysis
Acting as a collector for NetFlow/IPFIX data from an entire enterprise fabric, the platform can ingest and process terabytes of flow records daily.
- **Key Requirement Met:** The massive memory bandwidth ensures that flow records are written quickly to the high-speed NVMe logging array, minimizing backpressure on the source routers and switches.
4. Comparison with Similar Configurations
To contextualize the NET-INFRA-X9000, we compare it against two common alternatives: a standard high-density compute server and a specialized, lower-power appliance.
4.1 Configuration Matrix Comparison
Feature | NET-INFRA-X9000 (Targeted) | Standard Compute Server (2U) | Network Appliance (Specialized, Low Power) |
---|---|---|---|
CPU Type | Dual Xeon Platinum (120C/240T) | Dual Xeon Gold (64C/128T) | Custom ARM/x86 SoC (8-16 Cores) |
Max Network Interface Speed | 2x 400GbE (Native) | 4x 100GbE (Via PCIe add-in) | 4x 25GbE (Onboard) |
PCIe Gen Support | Gen 5.0 (x16 slots) | Gen 4.0 (x16 slots) | Integrated PCIe Gen 3.0/4.0 |
Max RAM Capacity | 8 TB (DDR5) | 4 TB (DDR4) | 512 GB (DDR4) |
Expansion Slots for Accelerators | 5 Dedicated PCIe 5.0 Slots | 3 PCIe 4.0 Slots (Shared with Storage) | 0 (Fixed Function) |
Cost Index (Relative) | 100 | 65 | 40 |
4.2 Analysis of Trade-offs
The NET-INFRA-X9000’s superior performance comes at a significant cost premium (Cost Index 100) and higher operational expenditure (power/cooling).
- **Versus Standard Compute Server:** The primary advantage of the X9000 is the **PCIe 5.0 fabric** and the **sheer density of PCIe lanes**. Standard servers often lack enough lanes to support multiple 400GbE cards *and* dedicated acceleration hardware simultaneously without compromising storage performance. See PCIe Topology and Lane Allocation.
- **Versus Network Appliance:** Appliances are excellent for fixed workloads (e.g., a specific vendor's firewall software) but lack the flexibility to integrate custom software acceleration frameworks like DPDK or host multiple virtual network functions (VNFs) simultaneously, which the X9000 easily accommodates via virtualization layers (e.g., Kernel Bypass Networking).
5. Maintenance Considerations
Deploying a high-density, high-power server like the NET-INFRA-X9000 introduces specific requirements for the data center environment.
5.1 Thermal Management and Cooling
The combined TDP of the dual CPUs (700W) plus the high-power NICs and accelerators pushes the system well above standard server thermal envelopes.
- **Minimum Required Airflow:** The chassis requires a minimum sustained airflow of 120 CFM across the CPU heat sinks.
- **Rack Density:** Due to the high power draw, rack density must be limited. A standard 42U rack should host no more than 18 units of the X9000 if operating at 1200W per unit, assuming standard 2N cooling redundancy.
- **Temperature Thresholds:** BMC sensors must maintain CPU junction temperatures below 95°C under sustained 100% load. Exceeding 100°C will trigger automatic thermal throttling, leading to immediate performance degradation in critical network functions. Monitoring should use SNMP traps.
5.2 Power Requirements and Redundancy
The system is designed for dual, redundant power supplies, each rated for 2200W Platinum efficiency.
- **Input Voltage:** Supports 200-240V AC nominal input. Deploying at 120V is highly discouraged due to excessive current draw on the PDUs.
- **Circuit Loading:** Each server requires a dedicated 30A (208V) circuit at peak load. Standard 20A circuits are insufficient for full utilization.
- **Power Monitoring:** The BMCs must be configured to report real-time power consumption via Redfish to the DCIM system to prevent circuit overloads.
5.3 Component Replacement and Field Replaceable Units (FRUs)
Given the density, access to FRUs is critical for maintaining high availability.
1. **NIC Replacement:** The 400GbE cards are large and occupy primary slots. Replacement requires system shutdown and careful handling due to the sensitivity of the optical transceivers. Hot-swapping is NOT supported for these high-power components. 2. **Memory:** DIMMs are accessible from the front/rear, but replacement often requires temporarily removing the primary CPU heatsink shroud to access the rear DIMMs in a dual-socket configuration. 3. **Firmware Updates:** All firmware (BIOS, BMC, NIC/Adapter firmware) must be updated synchronously. Out-of-sync firmware, especially between the BIOS and specialized network adapter firmware, can lead to unexpected packet drops or PCIe link instability. Refer to the Firmware Management Procedures guide before any update cycle.
5.4 Network Configuration Best Practices
For optimal stability, the management plane and the data plane must be logically and physically separated, even when sharing the same NIC hardware via VLANs or SR-IOV virtualization.
- **Data Plane Isolation:** Use **SR-IOV Virtual Functions (VFs)** exclusively for high-speed packet forwarding to minimize hypervisor overhead.
- **Management Plane:** Use standard **Virtual Machines (VMs)** or dedicated OS instances for management tasks, connected via 1GbE or 10GbE virtual interfaces. Ensure the OOB management port (IPMI) is never routed onto the production network. See Network Segmentation Strategies.
The successful deployment of the NET-INFRA-X9000 relies heavily on these operational considerations to translate theoretical performance into sustained real-world throughput.
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️