This document provides a comprehensive technical overview and deployment guide for the **"EcoCore E1000"** server configuration, specifically engineered for maximum energy efficiency in high-density data center environments.
EcoCore E1000: The Energy-Efficient Server Configuration
The EcoCore E1000 platform represents a significant advancement in server design, balancing necessary computational throughput with industry-leading power utilization effectiveness (PUE) targets. This configuration prioritizes components with high performance-per-watt metrics, making it ideal for scale-out workloads sensitive to operational expenditure (OPEX) related to power and cooling.
1. Hardware Specifications
The EcoCore E1000 is built around a dense, single-socket architecture utilizing the latest low-power processor models and high-efficiency memory subsystems. All components have been rigorously selected based on their standardized power consumption ratings (TDP/TDP-P).
1.1 System Board and Chassis
The system utilizes a proprietary 1U rack-mount chassis (Model: EC-1U-GEN5) designed for optimal airflow management and reduced physical footprint.
Feature | Specification |
---|---|
Form Factor | 1U Rackmount (Depth: 750mm) |
Motherboard Chipset | Intel C741 Series (Optimized for Low-Power Profiles) |
Power Supply Units (PSUs) | 2 x 1000W 80 PLUS Titanium Certified (Redundant, Hot-Swappable) |
Cooling Solution | Direct-to-Chip Liquid Cooling Interface Ready (Standard configuration uses high-efficiency passive heatsinks with redundant 40mm fans) |
Backplane Support | NVMe/SATA/SAS Tri-Mode Support |
1.2 Central Processing Unit (CPU)
The configuration mandates the use of AMD EPYC processors featuring the "Zen 4c" core architecture, specifically those designated with the 'P' suffix (e.g., EPYC 9334P or equivalent), which offer higher core density at lower base frequencies and reduced TDP envelopes compared to general-purpose SKUs.
Parameter | Specification |
---|---|
Processor Model | AMD EPYC 9334P (Example SKU) |
Core Count | 32 Cores / 64 Threads |
Base Clock Frequency | 2.7 GHz |
Max Boost Frequency | 3.4 GHz (Limited via BIOS power capping) |
Thermal Design Power (TDP) | 165W (Configured for sustained operation at 150W maximum package power) |
L3 Cache | 128 MB |
Socket Configuration | Single Socket (1P) |
Advanced power management on the CPU is mandatory, utilizing specific Intel SST or AMD equivalents to aggressively downclock non-critical cores during idle states.
1.3 Memory Subsystem (RAM)
To maximize efficiency, the system employs Registered Dual In-line Memory Modules (RDIMMs) operating at lower voltages (1.1V standard). The configuration is optimized for *memory density per watt*.
Parameter | Specification |
---|---|
Memory Type | DDR5 ECC RDIMM |
Total Capacity | 512 GB (16 x 32 GB DIMMs) |
Memory Speed | 4800 MT/s |
Voltage (VDD) | 1.1V |
Configuration Density | 16 DIMM slots populated (Maximum capacity utilization) |
Power Draw Estimate (Total) | ~75W under full load |
The use of LVDS signaling on the memory channels contributes to reduced signal integrity power overhead.
1.4 Storage Subsystem
Storage selection emphasizes low-power consumption while maintaining high IOPS required for transactional workloads. Traditional spinning disks (HDDs) are strictly prohibited in this configuration.
Slot | Type | Capacity | Power Rating (Estimated) |
---|---|---|---|
NVMe Slots (M.2/U.2) | 4 x PCIe Gen5 NVMe SSDs | 3.84 TB Each (Total 15.36 TB) | ~5W per drive (Active read/write) |
SATA/SAS Bays (Front Load) | 8 x 2.5" SATA SSDs (Optional for bulk log storage) | 1.92 TB Each | ~2W per drive (Active) |
The primary boot and operational storage relies exclusively on high-efficiency NVMe devices, which exhibit superior performance-per-watt compared to SAS/SATA SSDs.
1.5 Networking and I/O
Networking is critical, as I/O overhead can significantly impact overall power draw. The configuration mandates high-efficiency network interface controllers (NICs).
Component | Specification |
---|---|
Baseboard Management Controller (BMC) | ASPEED AST2600 (Low-Power Mode Enabled) |
Onboard LAN (LOM) | 2 x 10GbE (Integrated into SoC, using C-State optimization) |
Expansion Slots (PCIe) | 2 x PCIe 5.0 x16 slots |
Optional Network Adapter | 1 x Mellanox ConnectX-7 100GbE (Max Power Draw: 18W) |
The LOM is configured to utilize the deepest possible C-states when network traffic is low, minimizing static power leakage.
2. Performance Characteristics
The EcoCore E1000 is not designed for peak computational throughput (e.g., high-frequency CFD simulations) but rather for maximizing workload density within a fixed power envelope (e.g., 500W total system draw). Performance metrics are therefore framed in terms of **Workload Units per Watt (WU/W)**.
2.1 Power Consumption Analysis
The primary goal is maintaining a Total System Power (TSP) below 450W under sustained, typical operational load (75% CPU utilization, 60% Memory utilization, moderate I/O).
Component | Idle Power (W) | Load Power (W) |
---|---|---|
CPU (150W TDP configured) | 25 W | 150 W |
RAM (512GB DDR5) | 20 W | 75 W |
NVMe Storage (4x Primary) | 5 W | 20 W |
Motherboard/Chipset/Fans | 15 W | 35 W |
Total Estimated System Power | 65 W | 280 W |
The system's **Maximum Achievable Power (MAP)**, when all components run at peak capacity (e.g., stress testing), is capped at 420W via BIOS/IPMI configuration, ensuring compatibility with standard 10A/208V rack PDUs without tripping breakers in dense deployments.
2.2 Benchmarking Results
The following results are derived from standardized tests focusing on efficiency metrics: SPECpower_2006 and synthetic database transaction benchmarks.
2.2.1 SPECpower_2006 Results
The primary metric here is **Watts/SPECrate** or its inverse, **SPECrate/Watt**.
Configuration | Metric (SPECrate2017_fp_base / Watt) | Efficiency Delta vs. Baseline (High-Frequency 2S Server) |
---|---|---|
EcoCore E1000 (1P, Low-TDP) | 0.85 | +45% |
Standard 2P Server (2 x 250W TDP) | 0.58 | Baseline (0%) |
Previous Gen E7 (1P, High-TDP) | 0.41 | -35% |
- Note: Results are normalized against a reference 2-socket server running a 220W TDP CPU configuration.*
2.2.2 Database Transaction Performance
Using the TPC-C benchmark simulating Online Transaction Processing (OLTP), efficiency is measured in Transactions Per Minute per Watt (TPM/W).
The EcoCore E1000 excels due to its high-speed, low-latency NVMe subsystem and optimized memory access patterns.
Configuration | TPC-C Throughput (tpmC) | Power Draw (W) | Efficiency (tpmC/W) |
---|---|---|---|
EcoCore E1000 (32C/64T) | 350,000 | 295 | 1186.4 |
High-Frequency 2S (64C/128T) | 550,000 | 650 | 846.1 |
This demonstrates that while the EcoCore E1000 produces less raw throughput, it delivers approximately 40% better efficiency for database workloads that are sensitive to memory latency and I/O speed rather than raw core frequency.
2.3 Thermal Output
The reduced power consumption directly translates to lower heat rejection (BTU/hr).
- **Total Heat Rejection (Full Load):** Approximately 955 BTU/hr (280W dissipated as heat).
- **Impact on Cooling Infrastructure:** In a standard rack deploying 42 EcoCore E1000 units, the total heat load is ~119 kW, significantly lower than the 250 kW load generated by equivalent density using older, high-TDP 2U servers. This reduction directly lowers the requirement for CRAC unit capacity and operational costs.
3. Recommended Use Cases
The EcoCore E1000 is specifically architected for scale-out environments where density, power capping, and long-term operational expenditure minimization are paramount.
3.1 Web and Application Serving
This configuration is ideal for hosting stateless or mildly stateful web applications (e.g., Nginx, Apache, IIS). The 32 cores provide ample threading capacity for handling thousands of concurrent HTTP/HTTPS connections without requiring excessive clock speeds.
- **Benefit:** High density allows for more application instances per rack unit, reducing physical space requirements and associated power distribution costs.
3.2 Virtualization Density (VDI and General Purpose)
For VDI or general-purpose virtualization platforms (e.g., VMware ESXi, KVM), the 1P architecture with fast NVMe storage ensures low latency for virtual machine booting and small file operations.
- **Configuration Note:** When deploying VMs, administrators should utilize CPU pinning techniques to ensure workloads are consistently scheduled on the most power-efficient core clusters, avoiding unnecessary migration overhead. Hypervisor Power Management features must be enabled.
3.3 Big Data Analytics (Low-Latency Data Tiers)
In distributed data processing frameworks like Hadoop or Spark, the EcoCore E1000 serves excellently as a "Worker Node" tier, particularly where the data set fits comfortably within the 512GB of high-speed memory.
- **Use Case:** Serving as a cache layer or a node dedicated to in-memory data processing tasks, leveraging the low latency of the DDR5 subsystem.
3.4 Microservices and Container Orchestration
The 1P design simplifies licensing models for certain commercial operating systems and container orchestration platforms. The efficiency profile is perfectly suited for cloud-native deployments where thousands of containers must be managed within strict power budgets. Refer to Container Resource Management best practices for optimal scheduling.
3.5 Storage Gateways and Proxies
For environments requiring high-speed data ingress/egress or acting as a secure gateway, the combination of fast 100GbE networking potential and low-power SSDs makes this an excellent choice for minimizing the power footprint of infrastructure services.
4. Comparison with Similar Configurations
To illustrate the value proposition of the EcoCore E1000, it is essential to compare it against two common alternatives: the traditional High-Performance (HP) server and a lower-density, high-frequency (HF) configuration.
4.1 Configuration Profiles
Feature | EcoCore E1000 (Efficiency Focus) | High-Performance (HP) Configuration | High-Frequency (HF) Configuration |
---|---|---|---|
Socket Count | 1P | 2P | 1P |
CPU TDP (Max) | 165W | 2 x 350W | 250W |
Total Cores (Approx.) | 32 | 128 | 24 |
Total RAM Capacity | 512 GB DDR5 | 1 TB DDR5 | 256 GB DDR5 |
Primary Storage | 15 TB NVMe (PCIe 5.0) | 30 TB SAS SSD | 8 TB NVMe (PCIe 4.0) |
Typical System Power Draw | 280 W | 850 W | 350 W |
4.2 Performance vs. Efficiency Trade-off
The comparison clearly shows that the EcoCore E1000 sacrifices peak computational throughput (e.g., 3D rendering, heavy simulation) in favor of superior operational efficiency.
Metric | EcoCore E1000 | High-Performance (HP) | High-Frequency (HF) |
---|---|---|---|
Peak Floating Point Operations (TFLOPS) | 1.8 TFLOPS | 6.5 TFLOPS | 1.5 TFLOPS |
Power Efficiency (Workload Units / Watt) | 1.25 WU/W | 0.76 WU/W | 0.95 WU/W |
Rack Density (Units per 42U) | 42 | 21 | 42 |
Estimated 5-Year OPEX (Power Only, per Server) | $1,800 | $5,500 | $2,300 |
The EcoCore E1000 achieves the highest **Rack Density Efficiency** (Workloads per Rack Unit) when considering the power draw, as it allows significantly more compute nodes per power circuit compared to the HP configuration. While the HF configuration offers similar density, its lower overall efficiency results in higher long-term power costs.
4.3 Comparison with Liquid Cooling
While the EcoCore E1000 is air-cooled in its base configuration, its low TDP makes it an excellent candidate for future upgrades to direct-to-chip liquid cooling.
- **Air-Cooled Performance:** Limited by the 165W TDP ceiling imposed by passive cooling constraints.
- **Liquid-Cooled Potential:** If liquid cooling were implemented (see Direct Liquid Cooling Implementation Guide), the system could safely sustain 220W TDP components, pushing performance up by approximately 30% while maintaining high efficiency relative to traditional air-cooled servers running at the same TDP.
5. Maintenance Considerations
Energy-efficient hardware often requires stricter adherence to specific operational parameters, particularly regarding environmental controls and firmware management.
5.1 Power Delivery and Redundancy
The use of 80 PLUS Titanium 1000W PSUs is crucial. These units achieve 94-96% efficiency at typical operational loads (50-75%). Using lower-rated PSUs (e.g., Platinum or Gold) would introduce unnecessary conversion loss, negating the efficiency gains made at the component level.
- **PDU Requirements:** Deploy these servers on Power Distribution Units (PDUs) configured for 208V or higher input whenever possible. Efficiency loss in the PSU is lower at higher input voltages (i.e., 208V is preferred over 120V).
- **Power Capping Enforcement:** Ensure that the server firmware (BIOS/IPMI) is configured to strictly enforce the MAP limit (420W). This prevents transient spikes from overloading facility power infrastructure, a common issue in dense, highly efficient deployments.
5.2 Thermal Management and Airflow
Although the total heat output is lower, maintaining precise airflow is vital for the longevity and performance consistency of the low-power components.
- **Minimum Airflow Requirements:** Maintain a minimum ambient intake temperature of 18°C (64.4°F) and a maximum of 27°C (80.6°F) as per ASHRAE Class A1/A2 standards.
- **Fan Control:** The system fans operate at significantly lower RPMs under normal load. Monitoring fan speed via the IPMI is necessary. Any sudden increase in fan speed when utilization is low likely indicates a blockage or a degradation in the heat sink contact, leading to thermal throttling. Server Fan Control Logic must be set to "System Load" rather than "Temperature Setpoint" for optimal energy savings.
5.3 Firmware and Power State Management
The energy efficiency of this configuration is fundamentally tied to sophisticated firmware algorithms that manage CPU C-states, memory power gating, and I/O power cycling.
1. **BIOS Updates:** Regularly update the BIOS and BMC firmware. Manufacturers frequently release microcode updates that enhance power management features (e.g., improved dynamic voltage and frequency scaling, or DVFS). 2. **OS Integration:** Ensure the operating system kernel is configured to utilize hardware power states aggressively. For Linux, this often means using the `cpufreq` governor set to `powersave` or relying on hardware-managed governors like `schedutil` when appropriate. Refer to Operating System Power Configuration guides. 3. **Storage Power Cycling:** Implement policies to aggressively power down NVMe drives that have been idle for more than 30 minutes. NVMe devices support low-power states (L1.2), which can reduce idle drive power consumption from 5W to under 1W.
5.4 Component Lifespan Considerations
Operating components at lower thermal envelopes generally increases their Mean Time Between Failures (MTBF). However, certain efficiency trade-offs require monitoring:
- **Memory Refresh Cycles:** In extreme low-power modes, memory refresh rates might be adjusted by the memory controller. While validated by the OEM, monitoring ECC error rates is crucial to ensure these aggressive power-saving settings do not introduce data corruption risks over extended periods.
- **PSU Cycling:** Due to the high efficiency of the Titanium PSUs, they often run cooler. However, the redundant nature (N+1) must be maintained. If one PSU fails, the remaining unit must be capable of handling 100% load without exceeding 90% utilization to maintain the required efficiency curve.
The EcoCore E1000 represents a strategic investment in sustainable IT infrastructure, demanding careful planning in deployment but yielding significant long-term operational savings.
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️