Technical Documentation: Server Configuration Template: Technical Documentation
This document provides a comprehensive technical deep dive into the server configuration designated as **Template: Technical Documentation**. This standardized build represents a high-density, general-purpose compute platform optimized for virtualization density and balanced I/O throughput, widely deployed across enterprise data centers for mission-critical workloads.
1. Hardware Specifications
The **Template: Technical Documentation** configuration adheres to a strict bill of materials (BOM) to ensure repeatable performance and simplified lifecycle management. This configuration is based on a dual-socket, 2U rackmount form factor, emphasizing high core count and substantial memory capacity.
1.1 Chassis and Platform
The foundation utilizes a validated 2U chassis supporting hot-swap components and redundant power infrastructure.
Feature | Specification |
---|---|
Form Factor | 2U Rackmount |
Motherboard Chipset | Intel C741 / AMD SP3r3 (Platform Dependent Revision) |
Maximum Processors Supported | 2 Sockets |
Power Supply Units (PSUs) | 2x 1600W 80+ Platinum, Hot-Swap, Redundant (N+1) |
Cooling Solution | High-Static Pressure, Redundant Fan Modules (N+1) |
Management Interface | Integrated Baseboard Management Controller (BMC) supporting IPMI 2.0 and Redfish API |
1.2 Central Processing Units (CPUs)
The configuration mandates two high-core-count, mid-to-high-frequency processors to balance single-threaded latency requirements with multi-threaded throughput demands.
Current Standard Configuration (Q3 2024 Baseline): Dual Intel Xeon Scalable (Sapphire Rapids generation, 4th Gen) or equivalent AMD EPYC (Genoa/Bergamo).
Parameter | Specification (Intel Baseline) | Specification (AMD Alternative) |
---|---|---|
Model Example | 2x Intel Xeon Gold 6444Y (16 Cores, 3.6 GHz Base) | 2x AMD EPYC 9354P (32 Cores, 3.25 GHz Base) |
Total Core Count | 32 Physical Cores (64 Threads) | 64 Physical Cores (128 Threads) |
Total Thread Count (Hyper-Threading/SMT) | 64 Threads | 128 Threads |
L3 Cache (Total) | 60 MB Per CPU (120 MB Total) | 256 MB Per CPU (512 MB Total) |
TDP (Per CPU) | 225W | 280W |
Max Memory Channels | 8 Channels DDR5 | 12 Channels DDR5 |
The selection prioritizes memory bandwidth, particularly for the AMD variant, which offers superior channel density crucial for I/O-intensive virtualization hosts. Refer to Server Memory Modules best practices for optimal population schemes.
1.3 Random Access Memory (RAM)
Memory capacity is a critical differentiator for this template, designed to support dense virtual machine (VM) deployments. The configuration mandates DDR5 Registered ECC memory operating at the highest stable frequency supported by the chosen CPU platform.
Parameter | Specification |
---|---|
Total Capacity | 1024 GB (1 TB) |
Module Type | DDR5 RDIMM (ECC Registered) |
Module Size | 8x 128 GB DIMMs |
Configuration | 8-channel population (Optimal for balanced throughput) |
Operating Frequency | 4800 MT/s (JEDEC Standard, subject to CPU memory controller limits) |
Maximum Expandability | Up to 4 TB (using 32x 128GB DIMMs, requiring specific slot population) |
Error Correction | Triple Modular Redundancy (TMR) supported at the BIOS/OS level for critical applications. |
Note: Population must strictly adhere to the motherboard's specified channel interleaving guidelines to avoid Memory Channel Contention.
1.4 Storage Subsystem
The storage configuration balances high-speed transactional capacity (NVMe) for operating systems and databases with large-capacity, persistent storage (SAS SSD/HDD) for bulk data.
1.4.1 Boot and System Storage
A dedicated mirrored pair for the Operating System and Hypervisor.
Parameter | Specification | |
---|---|---|
Type | M.2 NVMe SSD (PCIe Gen 4/5) | |
Quantity | 2 Drives (Mirrored via Hardware RAID/Software RAID 1) | |
Capacity (Each) | 960 GB | |
Endurance Rating (DWPD) | Minimum 3.0 Drive Writes Per Day |
1.4.2 Primary Data Storage
The primary storage array utilizes high-endurance NVMe drives connected via a dedicated RAID controller or HBA passed through to a software-defined storage layer (e.g., ZFS, vSAN).
Parameter | Specification |
---|---|
Drive Type | U.2 NVMe SSD (Enterprise Grade) |
Capacity (Each) | 7.68 TB |
Quantity | 8 Drives |
Total Usable Capacity (RAID 10 Equivalent) | ~23 TB (Raw: 61.44 TB) |
Controller Interface | PCIe Gen 4/5 x16 HBA/RAID Card (e.g., Broadcom MegaRAID 9660/9700 series) |
Cache (Controller) | Minimum 8 GB NV cache with Battery Backup Unit (BBU) or Power Loss Protection (PLP) |
1.5 Networking and I/O
High-bandwidth, low-latency networking is essential for a dense compute platform. The configuration mandates dual-port 25/100GbE connectivity.
Interface | Specification |
---|---|
Primary Uplink (Data/VM Traffic) | 2x 100 Gigabit Ethernet (QSFP28) |
Management Network (Dedicated) | 1x 1 Gigabit Ethernet (RJ-45) |
Expansion Slots (PCIe) | 4x PCIe Gen 5 x16 slots available for specialized accelerators or high-speed storage fabrics (e.g., Fibre Channel over Ethernet (FCoE)) |
The selection of 100GbE is based on current data center spine/leaf architecture standards, ensuring the server does not become a network bottleneck under peak virtualization load. Further details on Network Interface Card Selection are available in supporting documentation.
2. Performance Characteristics
The performance profile of the **Template: Technical Documentation** is characterized by high I/O parallelism, balanced CPU-to-Memory bandwidth, and sustained operational throughput suitable for mixed workloads.
2.1 Synthetic Benchmarks (Representative Data)
Benchmarking focuses on standardized industry tests reflecting typical enterprise workloads. Results below are aggregated averages from multiple vendor implementations using the specified Intel baseline configuration.
2.1.1 Compute Throughput (SPEC CPU 2017 Integer Rate)
This measures sustained computational performance across all available threads.
Metric | Result | Notes |
---|---|---|
SPECrate2017_int_base | 650 | Reflects virtualization overhead capacity. |
SPECrate2017_int_peak | 725 | Measures peak performance with optimized compilers. |
2.1.2 Memory Bandwidth
Crucial for in-memory databases and high-transaction OLTP systems.
Metric | Result (Dual CPU, 1TB RAM) |
---|---|
Read Bandwidth | ~380 GB/s |
Write Bandwidth | ~350 GB/s |
Latency (First Access) | ~95 ns |
2.2 Storage I/O Performance
The performance of the primary NVMe array (8x 7.68TB U.2 drives in RAID 10 configuration) dictates transactional responsiveness.
Operation | IOPS (Sustained) | Latency (Average) |
---|---|---|
Random Read (Queue Depth 128) | 1,800,000 IOPS | < 100 µs |
Random Write (Queue Depth 128) | 1,550,000 IOPS | < 150 µs |
Sequential Throughput | 28 GB/s Read / 24 GB/s Write |
These figures confirm the configuration's ability to handle demanding database transaction rates (OLTP) and high-speed log aggregation without bottlenecking the storage fabric.
2.3 Power and Thermal Performance
Operational power consumption varies significantly based on CPU selection and workload intensity (e.g., AVX-512 utilization).
State | Typical Power Draw (Intel Baseline) | Maximum Power Draw (Stress Test) |
---|---|---|
Idle (OS Loaded) | 280W – 350W | N/A |
50% Load (Mixed Workloads) | 650W – 780W | N/A |
100% Load (Full CPU Stress) | 1150W – 1300W | 1550W (Approaching PSU capacity) |
The thermal design ensures that under maximum sustained load, the chassis temperature remains below the critical threshold of 45°C ambient intake, provided the data center cooling infrastructure meets minimum requirements (see Section 5).
3. Recommended Use Cases
The **Template: Technical Documentation** configuration is engineered for environments requiring high density, balanced I/O, and significant memory allocation per virtual machine or container.
3.1 Enterprise Virtualization Hosts
This is the primary intended deployment scenario. The 1TB RAM capacity and 32/64 cores support consolidation ratios of 50:1 or higher for typical general-purpose workloads (e.g., Windows Server, standard Linux distributions).
- **Virtual Desktop Infrastructure (VDI):** Excellent density for non-persistent VDI pools requiring high per-user memory allocation. The fast NVMe storage handles rapid boot storms effectively.
- **General Purpose Server Consolidation:** Ideal for hosting web servers, application servers (Java, .NET), and departmental file services where a mix of CPU and memory resources is needed.
3.2 Database and Analytical Workloads
While specialized configurations exist for pure in-memory databases (requiring 4TB+ RAM), this template offers superior performance for transactional databases (OLTP) due to its excellent storage subsystem latency.
- **SQL Server/Oracle:** Suitable for medium-to-large instances where the working set fits comfortably within the 1TB memory pool. The high core count allows for effective parallelism in query execution.
- **Big Data Caching Layers:** Functions well as a massive caching tier (e.g., Redis, Memcached) due to high memory capacity and low-latency access to persistent storage.
3.3 High-Performance Computing (HPC) Intermediary Nodes
For HPC clusters that rely heavily on high-speed interconnects (like InfiniBand or RoCE), this server acts as an excellent compute node where the primary bottleneck is often memory bandwidth or I/O access to shared storage. The PCIe Gen 5 expansion slots support next-generation accelerators or fabric cards.
3.4 Container Orchestration Platforms
Kubernetes and OpenShift clusters benefit immensely from the high core density and fast storage. The template provides ample room for running hundreds of pods across multiple worker nodes without exhausting local resources prematurely.
4. Comparison with Similar Configurations
To illustrate the value proposition of the **Template: Technical Documentation**, it is compared against two common alternatives: a high-density storage server and a pure CPU-optimized HPC node.
4.1 Configuration Matrix Comparison
Feature | Template: Technical Documentation (Balanced 2U) | Alternative A (High Density Storage 4U) | Alternative B (HPC Compute 1U) |
---|---|---|---|
Form Factor | 2U Rackmount | 4U Rackmount (High Drive Bays) | |
CPU Cores (Max) | 64 Cores (Intel Baseline) | 32 Cores (Lower TDP focus) | |
RAM Capacity (Max) | 1 TB (Standard) / 4 TB (Max) | 512 GB (Standard) | |
Primary Storage Bays | 8x U.2 NVMe | 24x 2.5" SAS/SATA SSD/HDD | |
Network Uplink (Max) | 100 GbE | 25 GbE (Standard) | |
Power Density (W/U) | Moderate/High | Low (Focus on density over speed) | |
Ideal Workload | Virtualization, Balanced DBs | Scale-out Storage, NAS | |
Cost Index (Relative) | 1.0 | 0.85 (Lower CPU cost) | 1.2 (Higher component cost for specialized NICs) |
4.2 Performance Trade-offs Analysis
The primary trade-off for the **Template: Technical Documentation** lies in its balanced approach.
- **Versus Alternative A (Storage Focus):** Alternative A offers significantly higher raw raw storage capacity (using slower SAS/SATA drives) at the expense of CPU core count and memory bandwidth. The Template configuration excels when the workload is compute-bound or requires extremely low-latency transactional storage access.
- **Versus Alternative B (HPC Focus):** Alternative B, often a 1U server, maximizes core count and typically uses faster, higher-TDP CPUs optimized for deep vector instruction sets (e.g., AVX-512 heavy lifting). However, the 1U chassis severely limits RAM capacity (often maxing at 512GB) and forces a reduction in drive bays, making it unsuitable for virtualization density. The Template offers superior memory overhead management.
The selection criteria hinge on the Workload Classification matrix; this template scores highest on the "Balanced Compute and I/O" quadrant.
5. Maintenance Considerations
Proper maintenance protocols are vital for sustaining the high-reliability requirements of this configuration, especially concerning thermal management and power redundancy.
5.1 Power Requirements and Redundancy
The dual 1600W PSUs are capable of handling peak loads, but careful planning of the Power Distribution Unit (PDU) loading is required.
- **Total Calculated Peak Draw:** Approximately 1600W (with 100% CPU/Storage utilization).
- **Redundancy:** The N+1 configuration means the system can lose one PSU during operation and still maintain full functionality, provided the remaining PSU can sustain the load.
- **Input Voltage:** Must be supplied by separate A-side and B-side circuits within the rack to ensure resilience against single power feed failures.
5.2 Thermal Management and Airflow
Heat dissipation is the most critical factor affecting component longevity, particularly the high-TDP CPUs and NVMe drives operating at PCIe Gen 5 speeds.
1. **Intake Temperature:** Ambient intake air temperature must not exceed 27°C (80.6°F) under sustained high load, as per standard ASHRAE TC 9.9 guidelines for Class A1 environments. 2. **Airflow Obstruction:** The rear fan modules rely on unobstructed exhaust paths. Blanking panels must be installed in all unused rack unit spaces immediately adjacent to the server to prevent hot air recirculation or bypass airflow. 3. **Component Density:** Due to the high density of NVMe drives, thermal throttling is a risk. Monitoring the thermal junction temperature (Tj) of the storage controllers is mandatory through the BMC interface.
5.3 Firmware and Driver Lifecycle Management
Maintaining synchronized firmware across the system is paramount, particularly the interplay between the BIOS, BMC, and the RAID/HBA controller.
- **BIOS/UEFI:** Must be updated concurrently with the BMC firmware to ensure compatibility with memory training algorithms and PCIe lane allocation, especially when upgrading CPUs across generations.
- **Storage Drivers:** The specific storage controller driver (e.g., LSI/Broadcom drivers) must be validated against the chosen hypervisor kernel versions (e.g., VMware ESXi, RHEL). Outdated drivers are a leading cause of unexpected storage disconnects under heavy I/O stress. Refer to the Server Component Compatibility Matrix for validated stacks.
5.4 Diagnostics and Monitoring
The integrated BMC is the primary tool for proactive maintenance. Key sensors to monitor continuously include:
- CPU Package Power (PPT monitoring).
- System Fan Speeds (RPM reporting).
- Memory error counts (ECC corrections).
- Storage drive SMART data (especially Reallocated Sector Counts).
Alert thresholds for fan speeds should be set aggressively; a 10% decrease in fan RPM under load may indicate filter blockage or pending fan failure.
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️ Content Providers: Server Configuration Documentation
1. Hardware Specifications
The "Content Providers" server configuration is a high-performance, scalable solution designed for delivering rich media content, serving large web applications, and handling high volumes of concurrent requests. This document details the specific hardware components and their configurations within this build. This configuration prioritizes I/O performance, network bandwidth, and memory capacity.
1.1. Processor (CPU)
The core of the Content Providers configuration utilizes dual 3rd Generation Intel Xeon Scalable processors. We specifically employ the Intel Xeon Gold 6338 (codenamed Ice Lake). These processors offer a balance of core count and clock speed, vital for handling diverse workloads.
Specification | Value |
---|---|
Manufacturer | Intel |
Model | Xeon Gold 6338 |
Core Count | 32 Cores per Processor |
Thread Count | 64 Threads per Processor |
Base Clock Speed | 2.0 GHz |
Max Turbo Frequency | 3.4 GHz |
Cache | 48 MB Intel Smart Cache (L3) |
TDP (Thermal Design Power) | 205W |
Socket Type | LGA 4189 |
Integrated Graphics | None (Dedicated GPUs are recommended, see section 1.5) |
The choice of the Gold 6338 provides excellent performance per watt and supports the required PCIe 4.0 lanes for high-speed storage and networking. See CPU Selection Criteria for a detailed explanation of this choice.
1.2. Memory (RAM)
The system is equipped with 512GB of DDR4 ECC Registered (RDIMM) memory, configured in a 16 x 32GB configuration. This provides ample memory capacity for caching frequently accessed content and handling large datasets. Memory speed is critical; we utilize 3200MHz modules to maximize bandwidth.
Specification | Value |
---|---|
Type | DDR4 ECC Registered (RDIMM) |
Capacity | 512 GB |
Speed | 3200 MHz |
Module Count | 16 |
Module Size | 32 GB |
Memory Channels | 8 (Dual-Rank per channel) |
Memory Protection | ECC (Error-Correcting Code) |
Form Factor | DIMM |
ECC memory is crucial for server stability and data integrity, particularly when serving critical content. See Memory Subsystem Design for more details.
1.3. Storage
Storage is a critical component, and the Content Providers configuration utilizes a tiered approach for optimal performance and cost-effectiveness:
- **Boot Drive:** 480GB NVMe PCIe 4.0 SSD (Samsung 980 Pro) – for operating system and frequently accessed system files.
- **Cache Tier:** 4 x 1.92TB NVMe PCIe 4.0 SSDs (Intel Optane P4800X) – These are used as a high-speed cache for frequently requested content, significantly reducing latency. This utilizes a RAID 0 configuration for maximum performance.
- **Capacity Tier:** 8 x 16TB SAS 12Gbps 7.2K RPM HDDs – Provides bulk storage for less frequently accessed content. Configured in RAID 6 for redundancy and data protection.
Storage Tier | Drive Type | Capacity | Interface | RAID Configuration | Performance Characteristics |
---|---|---|---|---|---|
Boot | NVMe PCIe 4.0 SSD | 480 GB | PCIe 4.0 x4 | RAID 0 (Single Drive) | High IOPS, Low Latency |
Cache | NVMe PCIe 4.0 SSD (Optane) | 1.92 TB x 4 | PCIe 4.0 x4 | RAID 0 | Extremely High IOPS, Very Low Latency |
Capacity | SAS 7.2K RPM HDD | 16 TB x 8 | SAS 12Gbps | RAID 6 | High Capacity, Moderate IOPS |
See Storage Hierarchy and RAID Levels for a complete discussion of these technologies.
1.4. Network Interface Cards (NICs)
Network connectivity is paramount. This configuration features dual 100GbE NICs (Mellanox ConnectX-6), providing high bandwidth and low latency for content delivery. These NICs support RDMA over Converged Ethernet (RoCEv2) for optimized performance with compatible storage and networking infrastructure. A 1GbE management NIC is also included.
Specification | Value |
---|---|
Primary NICs | Mellanox ConnectX-6 |
Bandwidth | 100 GbE x 2 |
Ports | 2 x QSFP28 |
Technology | RDMA over Converged Ethernet (RoCEv2) |
Management NIC | Intel X710-DA4 |
Management Bandwidth | 1 GbE |
See Networking Technologies for Servers for more information on RoCEv2 and other networking options.
1.5. Graphics Processing Units (GPUs)
While not strictly *required*, the inclusion of GPUs significantly enhances performance for specific workloads, such as video transcoding or image processing. We recommend two NVIDIA Tesla T4 GPUs. These GPUs offer a good balance of performance and power efficiency.
Specification | Value |
---|---|
Manufacturer | NVIDIA |
Model | Tesla T4 |
GPU Memory | 16 GB GDDR6 |
CUDA Cores | 2560 |
Power Consumption | 70W |
See GPU Acceleration in Servers for details on GPU integration.
1.6. Power Supply Unit (PSU)
A redundant 1600W 80+ Platinum PSU ensures high availability and efficient power delivery. The redundancy prevents downtime in case of PSU failure.
Specification | Value |
---|---|
Type | Redundant |
Wattage | 1600W |
Efficiency Rating | 80+ Platinum |
Redundancy | N+1 |
See Power Supply Considerations for Servers for more details.
2. Performance Characteristics
The Content Providers configuration demonstrates excellent performance across a range of benchmarks and real-world scenarios.
2.1. Benchmarks
- **SPECvirt_sc2013:** Score of 850 (represents virtualized server performance).
- **IOzone:** Sequential Read: 18 GB/s, Sequential Write: 15 GB/s (using RAID 0 cache tier).
- **Web Server Benchmark (Apache ab):** Sustained 500,000 requests per second with a 99.9% success rate.
- **Video Transcoding (Handbrake):** 1080p transcoding at 60fps (using NVIDIA Tesla T4 GPUs).
- **Network Throughput (iperf3):** 95 Gbps sustained throughput between two servers with 100GbE NICs.
2.2. Real-World Performance
In a simulated content delivery scenario, the server was able to serve 10,000 concurrent users with an average response time of 200ms. Caching efficiency with the Optane SSDs resulted in a 70% reduction in latency for frequently accessed content. The dual 100GbE NICs prevented network bottlenecks, even under peak load. See Performance Monitoring and Analysis for details on testing methodologies.
2.3. Scalability
The modular design of this configuration allows for easy scalability. Additional RAM, storage, and GPUs can be added as needed to accommodate growing demands. The server chassis supports up to 16 DIMM slots and multiple PCIe expansion slots.
3. Recommended Use Cases
This configuration is ideally suited for the following applications:
- **Content Delivery Networks (CDNs):** Serving static and dynamic content to a global audience.
- **Video Streaming:** Handling high volumes of video streams, including live and on-demand content.
- **Web Application Hosting:** Hosting resource-intensive web applications that require high performance and scalability.
- **Large File Serving:** Distributing large files (e.g., software downloads, multimedia assets) quickly and reliably.
- **Database Caching:** Acting as a caching layer for databases to improve response times.
- **Virtual Desktop Infrastructure (VDI):** Supporting a moderate number of virtual desktops (with GPU acceleration).
4. Comparison with Similar Configurations
The Content Providers configuration represents a balance between performance, scalability, and cost. Here's a comparison with similar options:
Configuration | Content Providers (This Document) | High-Performance Database Server | Basic Web Server |
---|---|---|---|
CPU | Dual Intel Xeon Gold 6338 | Dual Intel Xeon Platinum 8380 | Dual Intel Xeon Silver 4310 |
RAM | 512 GB DDR4 3200MHz | 1TB DDR4 3200MHz | 64 GB DDR4 2666MHz |
Storage | Tiered: NVMe Cache, SAS Capacity | All NVMe SSD (High IOPS) | SATA HDD (High Capacity, Low Cost) |
Network | Dual 100GbE | Quad 100GbE | Dual 1GbE |
GPU | Optional: Dual NVIDIA Tesla T4 | Often Included: High-End NVIDIA GPUs | Typically None |
Cost | Moderate to High | Very High | Low to Moderate |
Primary Use Case | Content Delivery, Streaming, Web Apps | Database Workloads, Analytics | Simple Websites, Static Content |
The High-Performance Database Server prioritizes raw processing power and I/O performance, but at a significantly higher cost. The Basic Web Server offers a more cost-effective solution for less demanding workloads. See Server Configuration Comparison Matrix for a more extensive comparison.
5. Maintenance Considerations
Maintaining the Content Providers configuration requires careful attention to cooling, power, and software updates.
5.1. Cooling
The server generates a significant amount of heat, particularly with the high-performance CPUs and GPUs. A robust cooling solution is essential. This configuration requires a data center environment with adequate airflow and potentially liquid cooling for the GPUs. Regular monitoring of temperature sensors is crucial. See Data Center Cooling Best Practices.
5.2. Power Requirements
The server draws a maximum of 1600W. A dedicated circuit with sufficient capacity is required. The redundant PSU provides protection against power outages, but a UPS (Uninterruptible Power Supply) is recommended for mission-critical applications. See Server Power Management for details.
5.3. Software Updates
Regular software updates, including operating system patches, firmware updates, and driver updates, are essential for security and stability. A robust patch management system should be implemented. See Server Software Maintenance Procedures.
5.4. RAID Monitoring
Continuous monitoring of the RAID array is critical. Proactive replacement of failing drives is essential to prevent data loss. Automated alerting should be configured to notify administrators of any issues. See RAID Management and Monitoring.
5.5. Network Monitoring
Monitoring network performance and identifying potential bottlenecks is crucial for maintaining optimal content delivery speeds. Tools like Nagios or Zabbix can be used to monitor network traffic and latency. See Network Performance Monitoring.
Internal Links to Related Topics
CPU Selection Criteria Memory Subsystem Design Storage Hierarchy and RAID Levels Networking Technologies for Servers GPU Acceleration in Servers Power Supply Considerations for Servers Performance Monitoring and Analysis Server Configuration Comparison Matrix Data Center Cooling Best Practices Server Power Management Server Software Maintenance Procedures RAID Management and Monitoring Network Performance Monitoring Content Delivery Network Architecture Server Virtualization Best Practices
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️