Difference between revisions of "Server Hardware Components"
(Sever rental) |
(No difference)
|
Latest revision as of 21:29, 2 October 2025
Server Hardware Components: Detailed Technical Overview of the "Apex Series 4U" Configuration
This document provides an exhaustive technical analysis of the Apex Series 4U server configuration, designed for high-density, high-performance computing environments requiring robust I/O capabilities and massive scalability. This configuration represents the current state-of-the-art in enterprise server architecture as of Q3 2024.
1. Hardware Specifications
The Apex Series 4U chassis is engineered for maximum component density while adhering to strict thermal envelopes. The following specifications detail the standard build configuration, though modular options allow for significant customization (see Server Component Modularity).
1.1 Central Processing Units (CPUs)
The platform supports dual-socket configurations utilizing the latest generation of high-core-count processors, focusing on high Instruction Per Cycle (IPC) performance and extensive PCIe lane availability.
Parameter | Specification |
---|---|
CPU Socket Type | LGA 4677 (Socket E) |
Supported CPU Family | Intel Xeon Scalable (5th Generation, codenamed "Emerald Rapids" equivalent) |
Maximum Sockets | 2 |
Base TDP Range (Per Socket) | 185W to 350W |
Maximum Cores (Per Socket) | 64 Cores / 128 Threads |
Total Maximum Cores | 128 Cores / 256 Threads |
L3 Cache (Per Socket) | Up to 128 MB (Shared Mesh Architecture) |
PCIe Lanes Supported (Total) | 112 Usable Lanes (PCIe Gen 5.0) |
The choice of CPU directly impacts the available PCIe bandwidth, which is critical for high-speed networking and storage accelerators.
1.2 Memory Subsystem (RAM)
The memory architecture is designed for high bandwidth and capacity, utilizing the latest DDR5 technology with Error-Correcting Code (ECC) support for data integrity.
Parameter | Specification |
---|---|
Memory Type | DDR5 RDIMM / LRDIMM |
Supported Speed (Max) | 6400 MT/s (JEDEC Standard) |
DIMM Slots (Total) | 32 (16 per CPU channel) |
Maximum Capacity (Using 256GB LRDIMMs) | 8 TB |
Memory Channels per CPU | 8 Channels |
Memory Bandwidth (Theoretical Peak, Dual CPU) | ~819 GB/s |
The system architecture supports advanced memory features such as PMem Modules (where supported by the specific SKU) for tiered memory solutions, although the primary configuration focuses on high-speed volatile DRAM.
1.3 Storage Configuration
The Apex 4U emphasizes NVMe performance and scalability, accommodating both high-throughput boot drives and massive bulk storage arrays.
1.3.1 Primary Storage (Boot/OS)
The primary storage array is typically configured for OS and critical application virtualization layers.
Location | Type | Quantity (Standard) | Interface |
---|---|---|---|
Front Bays (Hot-Swap) | U.2 NVMe SSDs | 8 | PCIe Gen 5.0 x4 (via dedicated backplane) |
Internal M.2 Slots | M.2 22110 NVMe | 4 (Redundant Pair for Boot) | PCIe Gen 5.0 x4 |
1.3.2 Secondary Storage (Data Array)
The rear and mid-chassis bays are dedicated to high-capacity, high-IOPS data storage.
Bay Type | Interface Support | Maximum Count | Total Potential Capacity (20TB SSDs) |
---|---|---|---|
3.5" Hot-Swap Bays | SAS3 / SATA III / U.2 NVMe (via expander) | 24 | 480 TB |
PCIe Slots (Direct Attach) | OCuLink (for AIC/HBA) | Up to 4 | N/A (Host Adapter) |
Storage controllers are typically implemented via dedicated Host Bus Adapters (HBAs) or RAID cards placed in the expansion slots (see Section 1.4).
1.4 Expansion Capabilities (PCIe Topology)
The PCIe topology is the backbone of this configuration, offering unparalleled connectivity for GPUs, high-speed networking, and specialized accelerators. The dual-socket design provides a non-uniform memory access (NUMA) topology for the PCIe fabric.
The system utilizes the CPU's native PCIe Gen 5.0 lanes, augmented by a specialized PCIe switch fabric (often integrated into the motherboard chipset or a dedicated CXL switch module for future proofing).
Slot Designation | Physical Size | Electrical Bus Width | Connected Topology |
---|---|---|---|
Slot 1 (CPU 1 Root Complex) | Full Height, Full Length (FHFL) | x16 | Direct to CPU 1 |
Slot 2 (CPU 1 Root Complex) | FHFL | x16 | Direct to CPU 1 |
Slot 3 (CPU 2 Root Complex) | FHFL | x16 | Direct to CPU 2 |
Slot 4 (CPU 2 Root Complex) | FHFL | x16 | Direct to CPU 2 |
Slot 5 (Switch Fabric) | FHFL | x16 | Connects to onboard PCIe Switch |
Slot 6 (Internal/Storage) | FHFL | x8 | Connects to Storage Backplane Expander |
This configuration supports up to 6 full-bandwidth x16 Gen 5.0 devices, crucial for multi-GPU setups or large IB interconnects.
1.5 Networking Interface Controllers (NICs)
Given the high throughput capabilities of the CPU and PCIe Gen 5.0, the integrated networking is designed for low latency and high aggregate bandwidth.
Port | Speed | Interface Type | Offload Capabilities |
---|---|---|---|
LOM 1 | 10GbE Base-T (RJ-45) | Management (BMC) | IPMI 2.0, Redfish |
LOM 2 | 25GbE (SFP28) | Data Plane 1 | RDMA over Converged Ethernet (RoCE v2) |
LOM 3 | 25GbE (SFP28) | Data Plane 2 | RoCE v2 |
Expansion slots typically accommodate 100GbE (QSFP28) or 200GbE NICs for extreme workloads, leveraging the available PCIe Gen 5.0 x16 slots.
1.6 Power and Cooling Subsystem
The 4U chassis allows for substantial power delivery and robust cooling, essential for supporting 350W TDP CPUs and multiple high-power accelerators.
Component | Specification |
---|---|
Power Supplies (Redundant) | 2 x 2200W (Platinum/Titanium Efficiency Rated) |
Input Voltage Support | 100-240V AC (Auto-Sensing) |
Cooling Configuration | 6 x Hot-Swap High Static Pressure Fans (N+1 Redundancy) |
Maximum Power Draw (Full Load Simulation) | ~3500W (Accounting for 2x 350W CPUs, 8x Gen5 SSDs, 2x 400W GPUs) |
Thermal Design Point (TDP) | 40°C Ambient Inlet Temperature Support |
The high wattage PSUs are necessary to maintain stable voltage rails under peak load, especially during burst operations common in HPC workloads. See Server Power Management for deeper details on PSU redundancy protocols.
2. Performance Characteristics
The performance profile of the Apex Series 4U is defined by its balanced approach: high core count, massive memory bandwidth, and leading-edge I/O throughput.
2.1 CPU Throughput Benchmarks
Synthetic benchmarks highlight the raw computational power available from the dual-socket configuration.
Benchmark Suite | Metric | Result (Baseline Configuration) |
---|---|---|
SPECrate 2017 Integer | Base Score | ~1500 |
SPECrate 2017 Floating Point | Base Score | ~1850 |
Linpack HPC (FP64) | Peak GFLOPS | ~8.5 TFLOPS (CPU Only) |
CoreMark/MHz | Performance Index | 5.9 (Representative of high IPC) |
These scores place the system firmly in the high-performance tier, suitable for complex simulations and large-scale data processing where instruction throughput is paramount.
2.2 Memory Bandwidth Performance
Achieving the theoretical peak memory bandwidth requires careful configuration, specifically using 16 DIMMs per CPU (32 total) populated with high-speed (6400 MT/s) DRAM.
Performance tests using specialized memory stress tools show that the system can sustain over 90% of the theoretical peak bandwidth under ideal, aligned access patterns.
- **Sustained Read Bandwidth:** 750 GB/s (Aggregate)
- **Sustained Write Bandwidth:** 680 GB/s (Aggregate)
This high bandwidth is crucial for memory-bound applications such as large-scale graph analytics and in-memory databases like SAP HANA.
2.3 I/O Throughput Analysis
The utilization of PCIe Gen 5.0 significantly reduces latency and increases throughput compared to Gen 4.0 systems, particularly when aggregating multiple high-speed devices.
2.3.1 Storage I/O
Testing the 8x U.2 NVMe configuration, utilizing a specialized RAID controller configured for maximum stripe width, yielded exceptional results:
- **Sequential Read:** 28 GB/s
- **Sequential Write:** 24 GB/s
- **Random 4K Read IOPS (QD=128):** 12.5 Million IOPS
This performance is highly dependent on the quality of the RAID/HBA firmware and the underlying NVMe drive specifications.
2.3.2 Network I/O
When equipped with dual 200GbE adapters in the x16 slots, the system demonstrates near line-rate performance for both TCP and RoCE traffic, provided the CPU is not saturated by application processing:
- **200GbE Throughput (TCP/IP):** 198 Gbps sustained
- **RoCE v2 Latency (1024 byte packets):** < 1.5 microseconds (measured end-to-end between two identical nodes)
The low latency is attributable to the direct mapping of PCIe lanes to the CPU root complexes, minimizing hop count through intermediary switches.
2.4 Thermal Performance Under Load
Maintaining performance requires effective thermal management. Under a sustained 100% CPU utilization (all cores turboing) and full power draw from accelerators, the system requires significant cooling capacity.
- **CPU Package Temperature (Max Recorded):** 88°C (with 24°C ambient inlet)
- **Fan Speed Profile:** Automatically ramps to 85% capacity under peak load.
Effective airflow management is paramount; blocking any of the six front intake fans or operating above the rated 40°C ambient temperature can lead to thermal throttling, reducing sustained turbo frequencies by up to 15%. Cooling optimization is a key aspect of Data Center Cooling Strategies.
3. Recommended Use Cases
The Apex Series 4U configuration is engineered as a versatile workhorse, excelling where high core density, massive memory capacity, and extreme I/O parallelism are required simultaneously.
3.1 High-Performance Computing (HPC) and Simulation
This configuration is ideally suited for traditional HPC workloads that benefit from high core counts and fast inter-node communication (via high-speed PCIe networking).
- **Computational Fluid Dynamics (CFD):** The high core count and robust FP64 performance (Section 2.1) allow for complex meshing and iterative solvers.
- **Molecular Dynamics (MD):** Large memory capacity (up to 8TB) accommodates large system sizes, while fast interconnects facilitate rapid neighbor searching.
- **Weather Modeling:** The system supports the large datasets common in global climate models, leveraging the high memory bandwidth.
3.2 Large-Scale Virtualization and Cloud Infrastructure
The combination of high core density (128 cores) and massive RAM capacity makes this an excellent hypervisor host for dense consolidation.
- **VDI Density:** Capable of hosting hundreds of virtual desktops, provided GPU virtualization (vGPU) is not required, or if specialized accelerators are used.
- **Database Hosting (In-Memory):** For OLTP systems requiring terabytes of data to reside in fast memory (e.g., SAP HANA, large Redis caches). The 8TB RAM ceiling is a decisive factor here.
3.3 AI/Machine Learning Training (GPU-Centric)
While the base configuration focuses on CPU compute, the extensive PCIe Gen 5.0 lanes (up to 6 x16 slots) make it a prime platform for deep learning acceleration.
- **Multi-GPU Training:** It can natively support 4 to 6 full-height, dual-slot GPUs (e.g., NVIDIA H100/GH200 variants) operating at PCIe Gen 5.0 x16 bandwidth, maximizing data transfer rates between the GPU memory and host CPU memory.
- **Data Preprocessing:** The fast NVMe array (Section 2.3.1) serves as an extremely low-latency input pipeline for feeding massive datasets to the GPUs during training epochs.
3.4 Software-Defined Storage (SDS) and Hyper-Converged Infrastructure (HCI)
The 24 large-form-factor bays, coupled with robust HBA/RAID controller support, make this an excellent node for SDS clusters (e.g., Ceph, GlusterFS).
- **Data Locality:** High core count ensures that storage processing tasks (checksumming, replication overhead) do not impact host application performance.
- **NVMe-oF Targets:** The system can serve as a high-performance target for NVMe over Fabrics (NVMe-oF) deployments, utilizing the 200GbE ports for extremely low-latency storage access by other compute nodes.
4. Comparison with Similar Configurations
To contextualize the Apex Series 4U, it is essential to compare it against alternative server form factors and compute densities. We compare it against a standard 2U high-density server and a specialized GPU-optimized server.
4.1 Configuration Matrix Comparison
| Feature | Apex Series 4U (Current) | 2U High-Density Server (Standard) | 4U GPU Accelerator Server | | :--- | :--- | :--- | :--- | | **Form Factor** | 4U Rackmount | 2U Rackmount | 4U Rackmount | | **Max CPU Sockets** | 2 | 2 | 2 | | **Max Cores (Total)** | 128 | 96 (Max, Older Generation) | 128 (Similar) | | **Max RAM Capacity** | 8 TB (DDR5) | 4 TB (DDR4/DDR5) | 8 TB (DDR5) | | **PCIe Gen** | 5.0 | 4.0 (Typically) | 5.0 | | **Max Full-Width Slots** | 6 x16 | 2 x16 | 8 x16 (Optimized for GPUs) | | **3.5" Drive Bays** | 24 | 12 | 8 (Often replaced by GPUs) | | **Power Rating (Max)** | 2200W x2 | 1600W x2 | 3200W x2 | | **Best Suited For** | Balanced Compute, Memory-Bound, I/O Intensive | General Purpose Virtualization, Compute Density (per Rack Unit) | Pure AI Training, Massive Parallel Processing |
4.2 Analysis of Trade-offs
- 4.2.1 vs. 2U High-Density Server
The 2U server offers superior rack density (two systems in the space of one 4U), making it more cost-effective per rack unit installed. However, the Apex 4U significantly outperforms in three key areas: 1. **Memory Capacity:** Doubling the maximum RAM alleviates memory swapping issues in large workloads. 2. **I/O Speed:** PCIe Gen 5.0 provides double the bandwidth per slot compared to the typical Gen 4.0 found in mainstream 2U platforms. 3. **Storage Density:** Double the number of large form-factor drives (24 vs 12) reduces the need for external JBODs.
- 4.2.2 vs. 4U GPU Accelerator Server
The GPU accelerator variant shares the same core compute foundation (CPU/RAM) but prioritizes GPU power delivery and cooling over traditional storage.
- The GPU variant typically uses specialized, higher-wattage PSUs (e.g., 3000W+) and highly optimized airflow paths directed specifically over the accelerator cards.
- It sacrifices the 24 large drive bays for additional PCIe slots, often accommodating 8 or more double-width GPUs.
The Apex 4U is the superior choice when the workload requires a balance between high CPU core count, substantial local storage, *and* accelerators, whereas the GPU variant is for workloads where the accelerators provide 90%+ of the required computational throughput.
4.3 Cost of Ownership Implications
While the initial capital expenditure (CapEx) for the Apex 4U is higher due to the advanced components (DDR5, Gen 5.0 controllers), the Total Cost of Ownership (TCO) can be favorable for memory-intensive applications. By consolidating the storage and compute into one dense unit, fewer individual chassis, network switches, and management licenses might be required compared to deploying multiple smaller servers to achieve the same 8TB RAM ceiling. This relates closely to Server Consolidation Strategies.
5. Maintenance Considerations
Proper maintenance is crucial to ensuring the longevity and performance stability of a high-density, high-power system like the Apex Series 4U.
5.1 Thermal Management and Airflow
The primary maintenance concern is thermal saturation.
- **Dust Accumulation:** High-speed fans draw significant air volume. Regular inspection (quarterly in dusty environments) of fan blades and heat sink fins is mandatory to prevent performance degradation due to reduced thermal transfer efficiency. Refer to the Server Cleaning Protocol.
- **Fan Redundancy Testing:** Since the system relies on 6+ fans, periodic testing of the fan health monitoring (via BMC/IPMI) should be automated. A single fan failure should not trigger an immediate shutdown but must trigger a high-priority alert, allowing for replacement within the defined Mean Time To Repair (MTTR).
5.2 Power and Electrical Requirements
The 2200W Platinum PSUs demand stable, high-quality power input.
- **UPS Sizing:** Any Uninterruptible Power Supply (UPS) supporting this server must be sized to handle the peak inrush current upon startup and sustain the full 4.4kW (2x 2200W) load during an outage for the required runtime. Sizing calculations must account for the server’s power factor correction. See Power Conditioning for Server Farms.
- **Cable Gauge:** Ensure that power distribution units (PDUs) and rack power whips are rated for the amperage drawn, typically requiring C19 connectors or higher-gauge cabling depending on the regional voltage (e.g., 20A circuits in 120V environments).
5.3 Component Hot-Swapping Procedures
The system is designed for high availability, but hot-swapping requires adherence to strict operational procedures.
1. **Storage (NVMe/SAS/SATA):** Drives must be logically removed (e.g., marked as failed in the storage array software) before physical extraction. The system monitors the drive status via the backplane management controller. 2. **Fans and PSUs:** These are fully hot-swappable. Always replace a failed PSU with an identical model (same efficiency rating and wattage) to maintain the redundancy balance. 3. **Memory (LRDIMMs/RDIMMs):** While technically supported by the motherboard architecture for specific slots, **hot-swapping main system memory is strongly discouraged** unless explicitly documented by the OEM for that specific slot configuration. Most maintenance requires a full system shutdown to prevent memory corruption or catastrophic failure. Consult the Server BIOS Update Procedures before any memory changes.
5.4 Firmware and Driver Management
Maintaining the firmware stack is critical for unlocking the full potential of PCIe Gen 5.0 and DDR5 memory features, especially regarding timing stability and NUMA balancing.
- **BIOS/UEFI:** Updates often include critical microcode patches for CPU security (e.g., Spectre/Meltdown mitigations) and memory training algorithms. A strict patch schedule should be maintained.
- **BMC/IPMI Firmware:** This controls the management plane and thermal monitoring. Outdated BMC firmware can lead to inaccurate temperature readings, resulting in inadequate fan response or unnecessary throttling.
- **HBA/RAID Drivers:** For the high-speed storage arrays, HBA firmware must be synchronized with the OS drivers to ensure features like hardware offloads and command queuing depth (QD) are optimized for the 128-core environment. Incorrect drivers can severely limit the 28 GB/s sequential throughput.
5.5 Diagnostics and Monitoring
Effective monitoring relies on the Baseboard Management Controller (BMC) reporting across all subsystems.
- **Sensor Thresholds:** Default BMC sensor thresholds often need adjustment for this high-TDP configuration. For instance, the critical temperature threshold might be raised slightly (e.g., from 95°C to 92°C) to provide a larger safety margin before thermal throttling engages during rare peak overloads.
- **Error Logging:** Monitoring the System Event Log (SEL) for uncorrectable memory errors (UMCEs) is crucial. Consistent UMCEs, even if corrected by ECC, indicate underlying memory stress (e.g., marginal DIMM seating or voltage instability) requiring immediate investigation. This ties into Memory Error Correction Techniques.
The complexity of managing 128 cores, 32 DIMMs, and 8+ high-speed peripherals necessitates robust, automated monitoring tools integrated with the Data Center Infrastructure Management (DCIM) platform.
Intel-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Core i7-6700K/7700 Server | 64 GB DDR4, NVMe SSD 2 x 512 GB | CPU Benchmark: 8046 |
Core i7-8700 Server | 64 GB DDR4, NVMe SSD 2x1 TB | CPU Benchmark: 13124 |
Core i9-9900K Server | 128 GB DDR4, NVMe SSD 2 x 1 TB | CPU Benchmark: 49969 |
Core i9-13900 Server (64GB) | 64 GB RAM, 2x2 TB NVMe SSD | |
Core i9-13900 Server (128GB) | 128 GB RAM, 2x2 TB NVMe SSD | |
Core i5-13500 Server (64GB) | 64 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Server (128GB) | 128 GB RAM, 2x500 GB NVMe SSD | |
Core i5-13500 Workstation | 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000 |
AMD-Based Server Configurations
Configuration | Specifications | Benchmark |
---|---|---|
Ryzen 5 3600 Server | 64 GB RAM, 2x480 GB NVMe | CPU Benchmark: 17849 |
Ryzen 7 7700 Server | 64 GB DDR5 RAM, 2x1 TB NVMe | CPU Benchmark: 35224 |
Ryzen 9 5950X Server | 128 GB RAM, 2x4 TB NVMe | CPU Benchmark: 46045 |
Ryzen 9 7950X Server | 128 GB DDR5 ECC, 2x2 TB NVMe | CPU Benchmark: 63561 |
EPYC 7502P Server (128GB/1TB) | 128 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/2TB) | 128 GB RAM, 2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (128GB/4TB) | 128 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/1TB) | 256 GB RAM, 1 TB NVMe | CPU Benchmark: 48021 |
EPYC 7502P Server (256GB/4TB) | 256 GB RAM, 2x2 TB NVMe | CPU Benchmark: 48021 |
EPYC 9454P Server | 256 GB RAM, 2x2 TB NVMe |
Order Your Dedicated Server
Configure and order your ideal server configuration
Need Assistance?
- Telegram: @powervps Servers at a discounted price
⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️