Technical Deep Dive: Hybrid Cloud Architect Architectures (HCA) Server Configuration

This document provides a comprehensive technical specification and analysis of the reference server configuration optimized for deployment within a **Hybrid Cloud Architecture (HCA)**. This specialized configuration balances the high-performance demands of on-premises private cloud components (e.g., virtualization hosts, container orchestration platforms) with the necessary connectivity and security posture required for seamless integration with public cloud providers (e.g., AWS Outposts, Azure Stack HCI, Google Anthos).

The core philosophy behind this HCA server configuration is **Balanced Density and Interoperability**. It prioritizes high core count, substantial I/O bandwidth, and robust remote management capabilities over peak single-thread frequency, ensuring efficient resource pooling and low-latency interaction between the local environment and external cloud services.

1. Hardware Specifications

The HCA reference configuration is built upon a dual-socket, 2U rackmount platform, selected for its high expandability and optimized thermal envelope suitable for modern data center environments.

1.1 Core Processing Unit (CPU)

The CPU selection emphasizes high core density and support for advanced virtualization extensions (Intel VT-x/AMD-V) and trusted execution technologies (Intel SGX/AMD SEV) crucial for secure workload migration.

CPU Subsystem Specifications
Parameter Specification (Primary Selection) Specification (Alternative Selection)
Architecture Intel Xeon Scalable 4th Gen (Sapphire Rapids) AMD EPYC 9004 Series (Genoa)
Model Example Xeon Platinum 8460Y (56 Cores, 112 Threads) EPYC 9454 (48 Cores, 96 Threads)
Base Clock Speed 2.0 GHz 2.55 GHz
Max Turbo Frequency Up to 3.8 GHz (All-Core Avg. ~3.1 GHz) Up to 3.7 GHz (All-Core Avg. ~3.3 GHz)
L3 Cache (Total) 112.5 MB per socket (225 MB total) 128 MB per socket (256 MB total)
TDP (Thermal Design Power) 350W per socket 280W per socket
Memory Channels Supported 8 Channels DDR5 (4800 MT/s) 12 Channels DDR5 (4800 MT/s)
PCIe Generation Support PCIe Gen 5.0 PCIe Gen 5.0

The emphasis on high core count (minimum 96 physical cores per server) is critical for maximizing the density of virtual machines (VMs) and containers running orchestration layers like Kubernetes or OpenStack. The selection of CPUs supporting DDR5 ensures sufficient memory bandwidth to feed these cores, a common bottleneck in high-density virtualization environments.

1.2 Memory Configuration

Memory configuration is prioritized for capacity and speed, supporting the high paging rates often seen when provisioning numerous small-to-medium workloads typical in hybrid cloud bursting scenarios.

Memory Subsystem Specifications
Parameter Specification
Type DDR5 ECC Registered DIMM (RDIMM)
Speed/Frequency 4800 MT/s (PC5-38400)
Configuration 16 DIMMs per server (8 per CPU)
Total Capacity 1024 GB (16 x 64GB DIMMs)
Minimum Recommended Capacity 512 GB
Maximum Supported Capacity 4 TB (using 256GB LRDIMMs, if supported by motherboard/BIOS)
Memory Topology Optimal interleaving for 8-channel access (e.g., N+1 configuration)

1.3 Storage Subsystem Architecture

The storage architecture is designed for a tiered approach: ultra-fast local storage for hypervisor boot and critical metadata, and high-capacity NVMe for general workload storage, ensuring low-latency access that mimics public cloud block storage performance.

1.3.1 Boot and Metadata Storage (Tier 0)

This tier is reserved for the Operating System, hypervisor installation, and critical orchestration metadata (e.g., etcd clusters).

  • **Configuration:** 2 x 960GB NVMe M.2 SSDs (RAID 1 via onboard controller or dedicated PCIe RAID card).
  • **Purpose:** High availability and rapid boot times.

1.3.2 Primary Workload Storage (Tier 1)

This tier leverages high-performance, high-endurance NVMe drives connected directly via PCIe lanes for maximum throughput, essential for stateful workloads transitioning from the cloud.

  • **Configuration:** 8 x 3.84 TB Enterprise U.2 NVMe SSDs (PCIe Gen 4/5).
  • **RAID Configuration:** Typically configured as RAID 10 via a dedicated Hardware RAID Controller (e.g., Broadcom MegaRAID SAS 9580-8i configuration with NVMe support) or software RAID (e.g., ZFS/Storage Spaces Direct) utilizing the high core count.
  • **Total Usable Capacity (Estimated):** ~24 TB usable (after RAID 10 overhead).

1.3.3 Secondary/Archival Storage (Optional Tier 2)

For less latency-sensitive data, high-capacity SAS/SATA drives can be included, though often this role is offloaded entirely to the public cloud component of the HCA.

  • **Configuration:** Up to 8 x 16TB HDD (SAS 12Gb/s) in RAID 6.

1.4 Networking and Interconnect

Networking is the most critical differentiator for a Hybrid Cloud server, requiring high bandwidth for both east-west traffic (within the private cloud) and north-south traffic (to the public cloud interconnect).

Network Interface Cards (NICs) Specification
Port Type Quantity Speed/Interface Purpose
Management (OOB) 1 x Dedicated Port 1 GbE (RJ45) IPMI/BMC operations, independent of host OS.
Cluster/Storage Fabric 2 x Ports 200 GbE (QSFP-DD) Connectivity to Software-Defined Storage (SDS) or FCoE backend.
Cloud Interconnect (Uplink) 2 x Ports 100 GbE (QSFP28) Dedicated link to Cloud Gateway/Router, utilizing VXLAN or Geneve encapsulation.
Host Management/VM Traffic 2 x Ports 25 GbE (SFP28) Standard VM traffic and general external access.

The inclusion of 200 GbE interfaces is crucial for supporting infrastructure components like NVMe-oF or high-speed replication streams required for disaster recovery between the private and public clouds.

1.5 Management and Security

Robust out-of-band management is non-negotiable for HCA deployments where physical access may be geographically distant or deferred.

  • **Baseboard Management Controller (BMC):** Latest generation BMC (e.g., ASPEED AST2600 or equivalent) supporting Redfish API v1.2+ for modern automation integration with cloud orchestration tools.
  • **Trusted Platform Module (TPM):** TPM 2.0 required for hardware root-of-trust, essential for secure boot verification and integration with cloud identity services (e.g., AWS Nitro Enclaves compatibility features).
  • **Platform Firmware:** UEFI Secure Boot enabled; support for firmware attestation protocols.

2. Performance Characteristics

The HCA configuration is optimized for **throughput and predictability** rather than raw, peak computational bursts. Performance metrics must reflect multi-tenant, concurrent workload execution.

2.1 Virtualization Density Benchmarks

Testing focuses on the maximum sustainable number of virtual machines (VMs) that can run while maintaining agreed-upon Service Level Objectives (SLOs) for latency (e.g., <5ms response time for I/O operations).

  • **Test Environment:** VMware ESXi 8.0 or KVM hypervisor stack.
  • **Workload Mix:** 70% Web Servers (4 vCPUs/8GB RAM), 20% Database VMs (8 vCPUs/32GB RAM), 10% CI/CD Agents (2 vCPUs/4GB RAM).
  • **Observed Density:** A dual-socket system, as specified (225MB L3 cache, 112 cores), consistently supports **450-500 standardized VMs** before resource contention impacts the 5ms I/O SLO threshold, provided the storage subsystem is concurrently saturated.

2.2 Storage I/O Metrics

Storage performance is paramount, as data gravity often dictates the feasibility of hybrid cloud operations.

Storage Performance Benchmarks (8 x 3.84TB U.2 NVMe in RAID 10)
Metric Result (Sequential Read/Write) Result (Random 4K Read/Write IOPS)
Sequential Throughput 28 GB/s Read, 24 GB/s Write N/A
Random IOPS (QD32) N/A 2.8 Million Read IOPS, 2.1 Million Write IOPS
Average Latency (99th Percentile) < 150 microseconds (µs) < 300 microseconds (µs)

These metrics are essential for validating low-latency data synchronization mechanisms used in storage migration tools between the local cluster and cloud-attached storage volumes.

2.3 Network Latency and Jitter

The 100GbE Cloud Interconnect must demonstrate minimal jitter to ensure predictable performance for synchronous cloud operations (e.g., database replication).

  • **Intra-Cluster Latency (200GbE):** < 1.5 µs (typical switch fabric latency).
  • **Cloud Uplink Latency (End-to-End to Cloud Gateway):** Target < 50 µs (dependent on physical distance and WAN optimization). Jitter variance must remain below 10 µs at 95% percentile under peak load. This is verified using specialized network testing tools capable of network performance monitoring at line rate.

2.4 Power Efficiency

Given the high core count, power consumption under typical load (75% utilization) is monitored closely.

  • **Peak Power Draw (Fully Loaded):** ~1800W (including 16 DIMMs, 8 NVMe drives, dual CPUs, and 200GbE NICs).
  • **Efficiency Metric (Performance per Watt):** Targeted performance index of 5500 VM-Marks per Kilowatt, balancing density against operational cost, a key consideration in hybrid environments where on-premises costs are directly comparable to public cloud billing.

3. Recommended Use Cases

This specific HCA configuration is architecturally designed to excel in deployments requiring tight coupling between local, high-performance resources and the scalability of public cloud infrastructure.

3.1 Disaster Recovery and Business Continuity (DR/BC) =

The high-capacity, low-latency storage subsystem makes this server an ideal **Secondary Recovery Site (DR Site)**.

  • **Functionality:** Hosting synchronized replicas of critical Tier 0 and Tier 1 applications running in the primary public cloud region.
  • **Advantage:** Rapid failover using technologies like VMware Site Recovery Manager (SRM) or cloud-native replication partners, leveraging the local 200GbE fabric for fast data synchronization when the connection is available, and maintaining operational continuity during cloud outages.

3.2 Cloud Bursting and Capacity Overflow =

For organizations with highly variable demand profiles (e.g., retail during holidays, financial modeling cycles).

  • **Functionality:** The HCA server acts as the baseline capacity, absorbing standard load. During peak demand, workloads are seamlessly migrated (or new instances spun up) into the public cloud.
  • **Requirement Fulfilled:** The standardized hardware specification ensures that workloads migrated via container images or standardized VM templates function identically in both environments, avoiding configuration drift.

3.3 Edge Computing and Hybrid Data Processing =

In scenarios where data must be processed locally due to regulatory compliance or extreme low-latency requirements, but the resulting aggregated data needs long-term storage or large-scale analytics in the cloud.

  • **Functionality:** Running local machine learning inference models or IoT data aggregation platforms. The high core count processes the data locally, and the 100GbE uplink efficiently transfers the smaller, processed datasets to the central cloud data lake (e.g., S3 compatible storage).

3.4 Private Cloud Platform Hosting =

Serving as the foundational hardware layer for implementing a software-defined private cloud stack designed for interoperability.

  • **Examples:** Deploying OpenShift Container Platform or VMware Cloud Foundation components that require direct, low-latency access to the underlying hardware resources (e.g., direct hardware access for GPU passthrough in AI workloads, which is often restricted or costly in public clouds).

4. Comparison with Similar Configurations

To understand the value proposition of the HCA server, it must be contrasted against two common alternatives: a **High-Density Compute Node** (optimized purely for local virtualization) and a **Cloud Gateway Appliance** (optimized purely for network connectivity).

4.1 Configuration Matrix Comparison

HCA Server vs. Alternatives Comparison
Feature HCA Reference Configuration (2U) High-Density Compute Node (2U) Cloud Gateway Appliance (1U)
CPU Core Count (Total) 112 Cores (Dual Socket) 160 Cores (Dual Socket, lower TDP)
Total RAM Capacity 1024 GB (DDR5) 2048 GB (DDR5)
Primary Storage Type 8 x U.2 NVMe (Tiered) 12 x SATA/SAS HDD (High Capacity)
Network Bandwidth (Max Uplink) 2 x 100 GbE + 2 x 200 GbE 2 x 40 GbE
Management Focus Redfish, TPM 2.0, Secure Boot Standard IPMI
Ideal Workload Balanced VM/Container Hosting, DR Purely High-Density Virtualization
Cost Index (Relative) 1.0 (Baseline) 0.85 (Lower storage cost) 0.60 (Lower CPU/RAM)

4.2 Analysis of Trade-offs

  • **Versus High-Density Compute Node:** The HCA trades off raw local density (fewer cores/less RAM) for vastly superior I/O bandwidth (200GbE/NVMe) and enhanced security features (TPM 2.0 integration). Pure compute nodes often rely on slower SATA/SAS storage, which is unacceptable for synchronous hybrid cloud operations requiring rapid data synchronization.
  • **Versus Cloud Gateway Appliance:** The Gateway focuses almost entirely on routing, encryption offload (e.g., IPsec acceleration), and tunneling protocols. It lacks the necessary CPU/RAM resources to host significant application workloads, functioning merely as a bridge, whereas the HCA hosts the primary application layer locally.

The HCA configuration occupies the crucial middle ground, ensuring that the local infrastructure can sustain the performance demands of the applications that *cannot* or *should not* reside in the public cloud, while maintaining the necessary high-speed links for seamless data exchange. This design philosophy aligns directly with modern cloud repatriation strategies as well.

5. Maintenance Considerations

Deploying high-density, high-I/O servers in a production HCA environment necessitates rigorous attention to thermal management, power redundancy, and streamlined firmware lifecycle management.

5.1 Thermal Management and Cooling

The combined TDP of dual 350W CPUs, high-speed DDR5 memory, and multiple high-power NVMe drives places significant thermal stress on the chassis.

  • **Chassis Requirements:** Must be rated for high-density cooling profiles (e.g., ASHRAE A2 or better). Server chassis fans must be capable of maintaining adequate airflow across the CPU heatsinks, often requiring high-static pressure fans.
  • **Airflow Strategy:** Hot aisle/cold aisle containment is mandatory. If deploying in standard racks, ensure a minimum of 40% open-face area for intake.
  • **Thermal Monitoring:** The BMC firmware must be configured to trigger alerts if CPU core temperatures exceed 90°C under sustained load, indicating potential airflow restrictions. Proper data center cooling infrastructure is critical.

5.2 Power Redundancy and Capacity

The peak draw of ~1800W mandates specific power infrastructure planning.

  • **Power Supplies (PSUs):** Dual, hot-swappable 2000W (2N Redundant) PSUs are required to support the peak load with sufficient headroom for future component upgrades (e.g., adding dedicated GPU accelerators).
  • **PDU Requirements:** Each rack unit must be fed by independent Power Distribution Units (PDUs) sourced from separate utility feeds (A/B power). The system must be capable of surviving the failure of one entire power chain without interruption, leveraging the internal PSU redundancy.
  • **Power Utilization Effectiveness (PUE):** Due to the high power density, monitoring and optimizing the rack PUE becomes more challenging; thus, efficient component selection (like the lower TDP AMD alternative) is sometimes preferred despite slightly lower core counts.

5.3 Firmware and Lifecycle Management

In a hybrid environment, the on-premises firmware must be kept aligned with the compatibility matrix of the public cloud provider's reference hardware (e.g., ensuring the BIOS version supports the required features for the public cloud's hypervisor parity layer).

  • **BMC Patching:** The BMC firmware must be updated concurrently with the host OS/hypervisor patches. Vulnerabilities in the BMC can expose the entire hybrid fabric to attack, bypassing OS-level security. Utilize Redfish scripting for automated, verifiable firmware updates across the fleet.
  • **Storage Driver Compatibility:** NVMe controller firmware and host bus adapter (HBA) drivers must be rigorously tested against the chosen storage virtualization layer (e.g., if using [[[Software Defined Storage|SDS]]]). Outdated firmware can introduce latent corruption or performance degradation impacting cloud synchronization integrity.
  • **Security Baselines:** Implement automated checks using Configuration Management Databases (CMDB) to verify that all security settings (TPM enablement, secure boot configuration, disabled legacy ports) conform to the organization's security baseline standard before allowing the host to join the production cloud fabric.

This configuration demands a higher level of operational maturity compared to standard virtualization deployments, directly reflecting its role as the critical bridge between private enterprise resources and the public cloud ecosystem.


Intel-Based Server Configurations

Configuration Specifications Benchmark
Core i7-6700K/7700 Server 64 GB DDR4, NVMe SSD 2 x 512 GB CPU Benchmark: 8046
Core i7-8700 Server 64 GB DDR4, NVMe SSD 2x1 TB CPU Benchmark: 13124
Core i9-9900K Server 128 GB DDR4, NVMe SSD 2 x 1 TB CPU Benchmark: 49969
Core i9-13900 Server (64GB) 64 GB RAM, 2x2 TB NVMe SSD
Core i9-13900 Server (128GB) 128 GB RAM, 2x2 TB NVMe SSD
Core i5-13500 Server (64GB) 64 GB RAM, 2x500 GB NVMe SSD
Core i5-13500 Server (128GB) 128 GB RAM, 2x500 GB NVMe SSD
Core i5-13500 Workstation 64 GB DDR5 RAM, 2 NVMe SSD, NVIDIA RTX 4000

AMD-Based Server Configurations

Configuration Specifications Benchmark
Ryzen 5 3600 Server 64 GB RAM, 2x480 GB NVMe CPU Benchmark: 17849
Ryzen 7 7700 Server 64 GB DDR5 RAM, 2x1 TB NVMe CPU Benchmark: 35224
Ryzen 9 5950X Server 128 GB RAM, 2x4 TB NVMe CPU Benchmark: 46045
Ryzen 9 7950X Server 128 GB DDR5 ECC, 2x2 TB NVMe CPU Benchmark: 63561
EPYC 7502P Server (128GB/1TB) 128 GB RAM, 1 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (128GB/2TB) 128 GB RAM, 2 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (128GB/4TB) 128 GB RAM, 2x2 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (256GB/1TB) 256 GB RAM, 1 TB NVMe CPU Benchmark: 48021
EPYC 7502P Server (256GB/4TB) 256 GB RAM, 2x2 TB NVMe CPU Benchmark: 48021
EPYC 9454P Server 256 GB RAM, 2x2 TB NVMe

Order Your Dedicated Server

Configure and order your ideal server configuration

Need Assistance?

⚠️ *Note: All benchmark scores are approximate and may vary based on configuration. Server availability subject to stock.* ⚠️